4-14
Section 4: Operation
Moseley SL9003Q
602-12016-01 Revision J
4.4.11 Alarms/Faults
4.4.11.1 ALARMS
Module Parameter
Nominal
Trip
Value
LED
Status
QAM RF TX
Reverse Power
0.05 Watt
> 0.25 Watt
VSWR
PA Current
1.8 Amp
> 3.0 Amp
LO Level
100%
< 50%
Exciter Level
100%
< 50%
QAM RF RX
RSL
-30 to –90 dBm
SIGNAL
LO Level
100%
< 50%
QAM MODEM
BER - >1.00E-04
MOD/DEM
LOCK
Synth Level
100%
< 50%
MOD/DEM LOCK
Modulator only
Modem Level
100%
< 50%
MOD/DEM LOCK
Alarm definition: A specific parameter is out of tolerance, but is NOT crucial for proper system operation.
ALARMS are cautionary only, and indicates a degradation in a system parameter.
Logging: All fault and alarm events are logged with the date and time.
Alarm screen reset: After viewing the screen, press ENTER to clear all logs entries. If the alarm has been
corrected, no new logs will be generated.
4.4.11.2 FAULTS
Module
Parameter
Nominal
Trip Value
LED Status
QAM RF TX
Forward Power
1.0 Watt
< 0.5 Watt
RADIATE
AFC Lock
Lock
Unlock
AFC LOCK
PA Temp
40 deg C
>80 deg C
QAM RF RX
AFC Lock
Lock
Unlock
AFC LOCK
QAM MODEM
AFC Lock
Lock
Unlock
MOD/DEM LOCK
Mbaud Lock
Unlock
MOD/DEM
LOCK
Dbaud Lock
Unlock
MOD/DEM
LOCK
Dfec Lock
Unlock MOD/DEM
LOCK
Fault definition: A specific parameter is out of tolerance and is crucial for proper system operation.
Logging: All fault and alarm events are logged with the date and time.
Fault screen reset: After viewing the screen, press ENTER to clear all logs entries. If the fault has been
corrected, no new logs will be generated.
Summary of Contents for Starlink SL9003Q
Page 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Page 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Page 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Page 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...