Section 5: Module Configuration
5-5
Moseley SL9003Q
602-12016-01 Revision J
D3/D4/D5:
D3 D4 D5 AUX
DATA
RATE
OFF OFF OFF 300
OFF OFF ON 600
OFF ON OFF 1200
(DEFAULT)
OFF ON ON 2400
ON OFF OFF 4800
ON OFF ON 9600
+
ON ON OFF 19200
+
ON ON ON 38400
+
The 9600, 19200, and 38400 selections must use CTS Line.
D6
: This switch is reserved.
D7
: This switch selects the test mode: OFF=Disabled (default), ON=Enabled.
D8
: This switch selects the debug mode: OFF=Normal (default), ON=Enabled.
5.2.6 Encoder: S22 - BOARD ID
A2 A3 A4 A5 A6 A7 A8 A9 Board# Base Address
OFF OFF OFF OFF OFF OFF OFF OFF 0
0
OFF ON OFF OFF OFF OFF OFF OFF 2
8
OFF OFF ON OFF OFF OFF OFF OFF 3
16
OFF OFF OFF ON OFF OFF OFF OFF 4
32
OFF OFF OFF OFF OFF ON OFF OFF 6
128
OFF OFF OFF OFF OFF OFF ON OFF 7
256
5.2.7 Encoder: S23 - SYSTEM CONFIG
R1/R2
: These switches select the Sample Rate Converter Data Source:
R1
R2
Sample Rate Converter Data Source
OFF OFF AES/EBU/SPDIF
(default)
OFF ON A/D
Converter
ON OFF Zeros
(Ground)
ON ON Sine
Generator
R3
: This switch selects the Bus Master Clock: OFF=Receive Clock from Mux Bus (default),
ON=Supply Clock to Mux Bus.
R4
: This switch selects Aux RS-232 Data: OFF=Diabled, ON=Enabled (default).
R5/R6
: These switches select 2-/4-Channel options:
R5 R6 2-/4-Channel
Select
OFF OFF 2-Channel
OFF ON Reserved
ON
OFF 4-Channel Master (1st Pair)
Summary of Contents for Starlink SL9003Q
Page 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Page 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Page 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Page 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...