5-20
Section 5: Module Configuration
Moseley SL9003Q
602-12016-01 Revision J
In a Transceiver
Relay 1: pins 7 (-) and 8 (+)
•
Tx control set OFF or transfer set COLD and unit is not Selected or Equipment Power Off:
Relay 1 = Off (Set Open)
•
Tx control set ON or AUTO or transfer set COLD and unit is selected and Equipment
Power On: Relay 1 = On (Set Closed)
Relay 2: pins 5 (-) and 6 (+)
•
Any Fault or Alarm or Equipment Power Off: Relay 2 = Off (Set Open)
•
No Faults or Alarms and Equipment Power On: Relay 2 = On (Set Closed)
Relay 3: pins 3 (-) and 4 (+)
•
Receive RSL < -100dBm or Equipment Power Off: Relay 3 = Off (Set Open)
•
Receive RSL > -100dBm and Equipment Power On: Relay 3 = On (Set Closed)
Relay 4: pins 1 (-) and 2 (+)
•
Pre-BER> 1E-4 or Equipment Power Off: Relay 4 = Off (Set Open)
•
Pre-BER < 1E-4 and Equipment Power On: Relay 4 = On (Set Closed)
5.8.3.2 Mapping Set 2 and “Map Faults-Relays” Set ON
Relays remain the same as for Mapping 1 but analog output is manually selected by
performing the following steps:
1) On the SL9003Q Tx Main Menu, use Up or Down arrow to select System
2) Press the <ENTER> button.
3) Scroll down to External I/O
4) Press the <ENTER> button.
5) Scroll down four times
6) Use left or right arrow to set analog output (see table in Mapping 1)
7) Press the <ENTER> button.
8) Press the <ESC> button twice
9) Use left or right arrow to select Yes to save settings
10) Press the <ENTER> button.
5.8.3.3 Mapping Set 0 and “Map Faults-Relays” Set ON
Analog output is manually selected. The relays are set as follows (refer to section 4.4.10 for
corresponding menu screens):
Relay 1: pins 7 (-) and 8 (+)
•
Receiver Synth UNLock Status Exist or Equipment Power Off: Relay 1 = Off (Set Open)
•
Receiver Synth Lock Status Exist and Equipment Power On: Relay 1 = On (Set Closed)
Relay 2: pins 5 (-) and 6 (+)
•
One or more Transmitter Alarm Status Exist or Equipment Power Off: Relay 2 = Off (Set
Open)
•
No Transmitter Alarm Status Exist and Equipment Power On: Relay 2 = On (Set Closed)
Summary of Contents for Starlink SL9003Q
Page 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Page 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Page 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Page 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...