5-18
Section 5: Module Configuration
Moseley SL9003Q
602-12016-01 Revision J
PVG612
Power MOSFET Photovoltaic Relay
Single Pole, NO, 0-60V, 2.0A DC, .15
Ω
S
D
G
D
+
LOAD
RELAY 4
2
1
Ext I/O
Figure 5-14. Representative Internal Relay Wiring
These relays are International Rectifier PVG612 series HEXFET Power MOSFET Photovoltaic
Relay, single-pole, normally-open. Interface parameters are given below:
Max. Voltage
60V
Max Current
2.0A
Open Resistance
100 M
Ω
Closed Resistance
0.15
Ω
5.8.3 Relay Mapping Configuration
5.8.3.1 Mapping Set 1 and “Map Faults-Relays” Set ON
The analog output is selected by connecting pins 17 and 18 to ground pins 19-23 in the
order shown below:
Analog Output
: Ext I/O pin 10
Digital Input
(external I/O connector):
#18 #17 OUTPUT
Open Open BER
Ground Open RSL
Open Ground
FWD
PWR
Ground Ground REV
PWR
To set the mapping, complete the following steps (refer to section 4.4.10 for corresponding
menu screens):
1) On the SL9003Q Tx Main Menu, use Up or Down arrow to select System
2) Press the <ENTER> button.
3) Scroll down to Unit-Wide Parameters
4) Press the <ENTER> button.
5) Scroll up once then down twice to select Mapping
6) Press the <ENTER> button.
Summary of Contents for Starlink SL9003Q
Page 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Page 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Page 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Page 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...