5
TerraMo - Instruction manual
1. Loosen the six screws, extend the device unit and switch off the power supply.
2. Pull out the device unit free of voltage.
3. Remove the interior accordingly.
4. Replace the device unit.
5. Screw the cover plate with the six screws.
6. Switch the mains supply back on.
lV. Maintenance and care
If after some time impurities have accumulated in the tub due to lifting and lowering,
remove them.
Basically applies:
Clean before lowering!
Lowering before loading!
Be sure to switch off the supply line fuse before opening!
V. Malfunctions
The system does not open when turning the hexagon key.
Explanation:
Heavy soiling
Solution:
Swivel the hexagon key slightly in the inserted state.
The system does not remain closed.
Explanation:
Impurities on the sealing surface
Solution:
Check the two seals on the lid.
For electrical or mechanical problems that cannot be fixed on site:
Switch off the power supply.
Loosen the six screws and extend the device unit.
Lift out the device unit.
Then cover the tray with a suitable cover.
Send the unit to our factory for troubleshooting.