102
Part Number: 000016427 Rev 00 08/2020
If the control board light does not respond to the float, proceed with Step 1 below.
1. Disconnect power to the ice machine and pull the float switch and connector through
the ice machine base and disconnect.
2. Attach an ohm meter lead to each float switch wire.
3. Place the float in the down position - The float switch must be closed.
4. Place the float in the up position - The float switch must be open.
5. If the float tests good, ohm the interconnecting wires to the control board and inspect
connectors.
NOTE: Make adjustments with the ice machine in the off position. Making adjustments
during the freeze cycle may produce an initial sheet of ice that is thicker than future cycles.
ICE THICKNESS
FLOAT
HARVEST
FLOAT