32
Part Number: 000016427 Rev 00 08/2020
Requirements - Cleaning - Operation
HARVEST SEQUENCE
5. Harvest
The water pump de-energizes stopping flow over the evaporator. The rising level of water
in the sump trough diverts water out of the overflow tube, purging excess minerals from
the sump trough. The harvest valve also opens to divert hot refrigerant gas into the
evaporator.
The refrigerant gas warms the evaporator causing the cubes to slide, as a sheet, off the
evaporator and into the storage bin. The sliding sheet of cubes contacts the ice damper,
opening the bin switch.
The momentary opening and re-closing of the bin switch terminates the Harvest Sequence
and returns the ice machine to the Freeze Sequence (steps 3 - 4).
AUTOMATIC SHUT-OFF
6. Automatic Shut-off
When the storage bin is full at the end of a harvest sequence, the sheet of cubes fails
to clear the ice damper and will hold it down. After the ice damper is held open for 7
seconds, the ice machine shuts off. The ice machine remains off for 3 minutes before it can
automatically restart.
The ice machine remains off until enough ice has been removed from the storage bin to
allow the ice to fall clear of the damper. As the ice damper swings back to the operating
position, the bin switch re-closes and the ice machine restarts (steps 1 - 2), provided the 3
minute delay period is complete.
Summary of Contents for PKM0335
Page 2: ......
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 131: ......
Page 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...