70
Part Number: 000016427 Rev 00 08/2020
Installation and Visual Inspection Checklist
Ice machine is not level
Level the ice machine
Condenser is dirty
• Clean the condenser
Water filtration is plugged (if used)
• Install a new water filter
Water drains are not run separately and/or are not vented
• Run and vent drains according to the Installation Manual
Water System Checklist
A water-related problem often causes the same symptoms as a refrigeration system
component malfunction.
Example: A water dump valve leaking during the freeze cycle, a system low on charge, and
a starving TXV have similar symptoms.
Water system problems must be identified and eliminated prior to replacing refrigeration
components.
Water area (evaporator) is dirty
• Clean as needed
Water inlet pressure not between 20 and 80 psig (1–5 bar, 138–552 kPa)
• Install a water regulator valve or increase the water pressure
Incoming water temperature is not between 35°F (1.7°C) and 90°F (32.2°C)
• If too hot, check the hot water line check valves in other store equipment
Water filtration is plugged (if used)
• Install a new water filter