84
Part Number: 000016427 Rev 00 08/2020
SUCTION PRESSURE HIGH CHECKLIST
Improper Installation
• Refer to “Installation and Visual Inspection Checklist” on page 70
Discharge Pressure
• Discharge pressure is too high, and is affecting suction pressure, refer to “Discharge
Pressure High Checklist” on page 81
Improper Refrigerant Charge
• Overcharged
• Wrong type of refrigerant
• Non-condensible in system
Other
• Non-OEM components in system
• Harvest valve leaking
• TXV flooding (check bulb mounting)
• Defective compressor
SUCTION PRESSURE LOW CHECKLIST
Improper Installation
• Refer to “Installation and Visual Inspection Checklist” on page 70
Discharge Pressure
• Discharge pressure is too low, and is affecting suction pressure, refer to “Freeze Cycle
Discharge Pressure Low Checklist” on page 81
Improper Refrigerant Charge
• Undercharged
• Wrong type of refrigerant
Other
• Non-OEM components in system
• Improper water supply over evaporator refer to “Water System Checklist” on page 70
• Loss of heat transfer from tubing on back side of evaporator
• Restricted/plugged liquid line drier
• Restricted/plugged tubing in suction side of refrigeration system
• TXV starving
NOTE: Do not limit your diagnosis to only the items listed in the checklists.
Summary of Contents for PKM0335
Page 2: ......
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 131: ......
Page 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...