Part Number: 000016427 Rev 00 08/2020 21
Requirements - Cleaning - Operation
PKU0155 Parts Removal
1. Remove Two Thumbscrews and Water Pump Cover.
2. Remove the Vinyl Hose Connecting the Water Pump and Water
Distribution Tube.
3. Remove Water Pump:
• Disconnect the water pump power cord.
• Loosen the screws securing the pump mounting bracket to the
bulkhead.
• Lift the pump and bracket assembly off the mounting screws.
4. Remove the Ice Thickness Probe by compressing the side of the ice
thickness probe near the top hinge pin and remove it from the
bracket.
NOTE: At this point, the ice thickness probe can easily be cleaned. If
complete removal is desired, follow the ice thickness probe wire to
the bulkhead grommet (exit point) in the back wall. Pop the bulkhead
grommet out of the back wall by inserting fingernails or a flat object
between the back wall and the grommet and prying forward. Pull the
bulkhead grommet and wire forward until the connector is accessible,
then disconnect the wire lead from the connector.
Ice Thickness Probe Cleaning
• Mix a solution of ice machine cleaner and water (2 ounces of cleaner to 16 ounces of
water) in a container.
• Soak the ice thickness probe a minimum of 10 minutes.
Clean all ice thickness probe surfaces and verify the ice thickness probe cavity is clean.
Rinse thoroughly with clean water, then dry completely. Incomplete rinsing and drying of
the ice thickness probe can cause premature harvest.
Summary of Contents for PKM0335
Page 2: ......
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 131: ......
Page 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...