Part Number: 000016427 Rev 00 08/2020 35
Requirements - Cleaning - Operation
WATER LEVEL CHECK PKU0155
The float valve is factory-set for the proper water level. If adjustments are necessary:
1. Verify the ice machine is level.
2. Remove the siphon cap from the standpipe.
3. Place the main ON/OFF/WASH toggle switch to the ON position, and wait until the
float valve stops adding water.
4. Adjust the water level to (1/4" to 3/8" [6.3 to 9.5 mm] below the standpipe) the line
in the water trough:
A. Loosen the two screws on the float valve bracket.
B. Raise or lower the float valve assembly as necessary, then tighten the screws.
5. Move the main ON/OFF/WASH toggle switch to the OFF position. The water level in
the trough will rise above the standpipe and run down the drain.
6. Replace the siphon cap on the standpipe, and verify water level and siphon action by
repeating steps 3 through 5.
ICE THICKNESS CHECK PKU0155
After a harvest cycle, inspect the ice cubes in the ice storage bin. The ice thickness probe is
set to maintain an ice bridge of 1/8" (3.2 mm). If an adjustment is needed, follow the steps
below.
1. Turn the ice thickness probe adjustment screw clockwise for a thicker ice bridge, or
counterclockwise for a thinner ice bridge.
2. Make sure the ice thickness probe wire and bracket does not restrict movement of
the probe.
Adjusting Screw
Summary of Contents for PKM0335
Page 2: ......
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 131: ......
Page 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...