66
Part Number: 000016427 Rev 00 08/2020
Troubleshooting Ice Thickness Control Circuitry
ICE MACHINE DOES NOT CYCLE INTO HARVEST WHEN WATER CONTACTS THE ICE
THICKNESS CONTROL PROBE
Step 1
Bypass the freeze time lock-in feature by moving the ON/OFF/WASH switch to
OFF and back to ON. Wait until the water starts to flow over the evaporator.
Step 2
Clip the jumper wire to the ice thickness probe and any cabinet ground.
EVAPORATOR
ICE THICKNESS
PROBE
PROBE
CONNECTION
GROUND
JUMPER
WIRE
BIN SWITCH
LIGHT (GREEN)
HARVEST
LIGHT (RED)
SV1592i
Step 2 Jumper wire connected from probe to ground
Monitoring Harvest Light
Correction
The harvest light comes on, and 6-10
seconds later, ice machine cycles from freeze
to harvest.
The ice thickness control circuitry is
functioning properly. Do not change any
parts.
The harvest light comes on but the ice
machine stays in the freeze sequence.
The ice control circuitry is functioning
properly. The ice machine is in a six minute
freeze time lock-in. Verify Step 1 of this
procedure was followed correctly.
The harvest light does not come on.
Proceed to Step 3.
Summary of Contents for PKM0335
Page 2: ......
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 131: ......
Page 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...