48
9.2 Malfunctions during the initial start-up
Behaviour/malfunction
Possible cause
Corrective action
Semi-automatic calibration
failed
Position of the markers not in the
correct ascending order (from 0 to 7)
of the numbering.
Place markers as specified.
See chapter "Laying out the calibration
markers" on page 24.
Marker hidden or not fully
recognizable.
The recognition of the markers may
be adversely affected by the light
conditions (e.g., light source / sun is
reflected).
Check marker positions and correct, if
necessary.
See chapter "Check the position of the
calibration markers" on page 26.
Basic setting of the 270°/360° system
is incorrect.
Select correct setting.
See chapter "Basic set 270° or 360°" on
page 22.
The cameras and the assigned inputs
are not correct.
Check the electrical connection and
assignment of the cameras to the inputs.
Manual calibration failed
Marker hidden or not fully
recognizable.
Check marker positions and correct, if
necessary.
See chapter "Laying out the calibration
markers" on page 24.
Basic setting of the 270°/360° system
is incorrect.
Select correct setting.
See chapter "Basic set 270° or 360°" on
page 22.
During manual calibration, the target
crosses were not placed in the
correct order.
Correct the arrangement of the target crosses
according to the specification.
See chapter "Manual calibration" on page 31.
Changed settings are no
longer available after a
restart.
The settings were not saved.
Repeat the settings and press
"Save".
See chapter "Saving the settings" on
page 28.