45
show an error message as shown below.
!
F L
:
!
L
:
.
!
C.
Voltage setting too small
The voltage is set too small that output current is unable to reach the setting
value. The screen will glimmer to show an error message as shown below.
L
F
!
:
!
:
.
L
L !
5.11
Programmable Capability (SCPI Command Only)
DS3640/DS6024/DS8018/DS10014 provides the capability for users to
program it. There are memory spaces to store 10 programs that can have 150
steps in total for setting purpose. Each program does not restrict the step
quantity, however, the sum of 10 programs are restricted to 150 steps. For each
program users can set up how many times to repeat the program. For each step
users may be able to set up the output voltage, current, and period of time (50
ms minimum) to output the settings. Please refer to
Sec 7.5.2 (SCPI command
subsystem)
for detail SCPI commands.