6.4
Constant Voltage Protection (CV TO CC)
When this function is activated DS3640/DS6024/DS8018/DS10014 will stay in
CV mode. If load changes and forces the system turning from CV to CC
(constant current) mode, system will enter the “ CV TO CC Protect” that will
shut off the output and display the CVC message on the screen. Press
to reset the protection and deactivate buzzer.
10 .
=
.
FF
.
6
3
=
.
6.5
Constant Current Protection (CC TO CV)
When this function is activated DS3640/DS6024/DS8018/DS10014 will stay in
the CC mode. If load forces the measurement turn from CC to CV (constant
voltage) mode, system will enter the “ CC TO CV Protect” that will shut off
output and display CCV message on the screen. Press
to reset the
protection and deactivate buzzer.
= 36 .
.
=
.
0
1
.
F
F
6.6
Over-temperature Protection (OTP)
When machine has detected abnormally high temperature, system will enter the
“ Over Temperature Protect” mode that will shut off output and display the erro
message as shown in the following figure. Press
to reset the protection
and deactivate buzzer.