26
6.5 SCPI Compatiable Information
The SCPI conforms to all specifications for devices as defined in IEEE-488.2 and
complies with SCPI command syntax version 1995.0. Confirmed Commands are
those commands which are approved commands in the SCPI 1995 Specification,
Volume 2: Command Reference.
6.5.1 SCPI Frequent Command
Command
Description
===========================================================
*CLS
Clear status (include error code)
*CAL?
As same as CALi? command,return calibration parameter
*IDN?
Response:<Manufacturer>, <model>, <serial number>,
<firmware type, & version>
*RCL
Recalls settings from memory. Memory numbers from 0 to 99 are
valid.
*RST
Resets the power supply to its power on state.
*SAV
1. Saves defined parameters
2. Saves current settings to memory. Memory numbers from 0 to
99 are valid.
*WAI
Sets the device to wait until all previous commands and queries
are complete before executing commands following the *WAI
command.
example:
Q15. How to save V/I to memory?
*SAV 15
==> Saves current settings to memory
number 15
SAV 0
==> Saves current settings to memory
number 0
Q16. How to recall memory V/I variable to output?
*RCL 3
==> recall setting from memory location 3
RCL 120
==> the data value is invalid
Q17. How to save configuration parameters?
SAV