9.3 In  solar  battery-charging  arrays,  blocking  diodes  are  required  to  prevent  the  solar  module  from  discharging  the  battery 

bank  at  night.  Motech  modules  do  not  include  blocking  diodes.  It  is  recommended  that  a  charge  controller  be  used  to 
prevent system batteries from being overcharged during the day and discharged at night. 

10. Equipment Ground 

In order to use safety and avoid damage to components by lightning and static electricity, all solar photovoltaic module borders 
and mounting brackets must be properly grounded in accordance with relevant national electrical regulations. Grounding wires 
can be copper, copper alloys, or other materials that can be used as conductors and comply with electrical regulations. When 
grounding, the grounding device must be fully in contact with the aluminum alloy inside the aluminium frame, to penetrate the 
oxide  film  on  the  border  surface,  each  grounding  hole  on  the  frame  of  the  assembly  is  marked. All  grounding  devices  must 
comply with relevant national regulations and usage requirements. 

11. Module Mounting 

11.1 Please do not artificial  gathered light on the surface of the module. 

 

11.2 The ambient temperature of the module installation is recommended to be between  -20°C and +46°C Celsius. Maximum     

operating temperature range -40°C ° Celsius to +85°C. 
 

11.3 The  minimum  safe  distance  between  the  module  and  the  module  is  recommended  for  1  cm  when  the  solar  panel  is  

installed. 
 

11.4 To ensure proper module mounting and a robust mounting system that allows the modulet to withstand all predetermined 

loads, the bracket installer must provide its warranty. 
 

11.5 The maximum power is 315W. It is recommended that the number of series not exceed 28 and the maximum number of 

parallels should not exceed 1. 
 

11.6 Each module has several drain holes to prevent water from accumulating in the aluminum frame. When installing, keep 

the drain holes unobstructed. The drain holes should not be blocked by the fixture to avoid water or ice in the frame after 
the cover, which may cause the frame to fail. 
 

11.7 The module is fixed to the mounting bracket as shown in Figure 2. The module can be bolted to the bracket or the fixture 

can be mounted using a clamp. If the fixture is used to secure the module to a bracket, the recommended fixture width is 

38mm  and  thickness  is 

4.5mm.  It  is  required  that  the  fixture  can  not  touch  the  glass  or  deform  the  frame  of  the 

component. The contact surface between the fixture and the frame must be smooth and smooth, otherwise the frame will 
be damaged and the components will be damaged. 
 

11.8 The solar module has passed the static mechanical test with a back load of 2400Pa and a front load of 5400Pa. Refer to 

Figure 1 and Figure 2 below for the fixture installation method: 

 

 

 

Figure 1.  White iron screw mounting hole 

 

Summary of Contents for XS60GB-315

Page 1: ...otech com tw Page Content 1 Disclaimer of Liability 2 2 Rules and regulations 2 3 Important Safety Information 2 4 Safe Work Practices 2 5 Fire installation needs 3 6 Unpacking and storage 3 7 Array D...

Page 2: ...ndling Do not apply bending or twisting forces to the module Do not step on the module or strike the front or back these actions may result in cracked solar cells Do not lift or carry the module by th...

Page 3: ...n be used in series or in parallel to produce the desired output voltage and output current When the modules are connected in series the output voltage of the entire string is the sum of the voltages...

Page 4: ...Vmpp V Impp A XS60GB 315 315 39 33 9 56 33 55 9 39 XS60GB 310 310 39 19 9 53 33 26 9 32 XS60GB 305 305 39 05 9 50 32 97 9 25 XS60GB 315 S 315 39 33 9 56 33 55 9 39 XS60GB 310 S 310 39 19 9 53 33 26 9...

Page 5: ...d to be between 20 C and 46 C Celsius Maximum operating temperature range 40 C Celsius to 85 C 11 3 The minimum safe distance between the module and the module is recommended for 1 cm when the solar p...

Page 6: ...ring Each Motech module is factory equipped with two lengths of 4 0mm 2 UL Recognized PV Wire 90 C rated sunlight resistant Factory cables are terminated with UL TUV Recognized electrical connectors A...