background image

Installation Manual  

 

 
 

6

MOTECH Industries, Inc., -  

Tainan Science Park ı No.2, Dashun 9th Rd., Xinshi Dist., Tainan City, 74145, Taiwan 

Tel: +886-6-5050789  |  E-mail

sale_marketing@motech.com.tw

                                                                           

    Page:  

 

 

 

XS60GB 

Figure 2, module installation diagram 

 

11.9 The maximum power generated by direct sunlight onto the solar components is the highest. In order to achieve the best 

output power of the components, the first is to select an unobstructed location for the whole year, and the second is to 
select  the  appropriate installation  angle.  A  rough  estimate is  that  the installation  of  the  optimal  tilt  angle  is basically  the 
same  as  the  local  latitude  at  the  installation  location.  If  the  component  is  mounted  on  a  roof  or  building  wall  for  heat 
dissipation, a fixed bracket must be used to maintain a 51mm gap between the roof or wall and the component. Do not 
install  directly  on  the  roof  or  wall.  The  mounting  bracket  is  required  to  have  sufficient  strength  to  withstand  all  possible 
stress loads, including wind and snow. 

12. Field Wiring 

 
Each Motech module is factory equipped with two lengths of 4.0mm

2

 UL-

Recognized “PV Wire” (90°C rated, sunlight resistant).  

Factory  cables  are  terminated  with  UL/TUV  Recognized  electrical  connectors.  Always  use  mating  connectors  of  the  same 
manufacturer to ensure compatibility.  DO NOT modify or replace the connectors provided with the module; doing so will void 
the  product  warranty.

 

The  waterproof  gasket  between  the  wire  and  the  junction  box  is  effective  to  prevent  moisture  from 

entering the junction box. To prevent moisture from entering the junction box from the wire, the deformation of the waterproof 
gasket should be reduced to improve its life. 

13. Connector 

The  wires  on  the  connector  and  the junction  box  are  not  tortuous  or  crimped.  The  corner  radius  of  the  wire  must  be  greater 
than  40mm.  The  installation  method  is  shown  in  Figure  3.  Avoid  keeping  the  wires  or  connectors  in  tension.  Improper 
installation causes the connector to burn out - the terminal crimping is not loose with standard tools and wires. 

 

Keep connectors clean and dry prior to installation.  Dirt and moisture may inhibit proper latching of the 
connector, which may lead to reduced system performance or failure of the connector. 

 

Summary of Contents for XS60GB-315

Page 1: ...otech com tw Page Content 1 Disclaimer of Liability 2 2 Rules and regulations 2 3 Important Safety Information 2 4 Safe Work Practices 2 5 Fire installation needs 3 6 Unpacking and storage 3 7 Array D...

Page 2: ...ndling Do not apply bending or twisting forces to the module Do not step on the module or strike the front or back these actions may result in cracked solar cells Do not lift or carry the module by th...

Page 3: ...n be used in series or in parallel to produce the desired output voltage and output current When the modules are connected in series the output voltage of the entire string is the sum of the voltages...

Page 4: ...Vmpp V Impp A XS60GB 315 315 39 33 9 56 33 55 9 39 XS60GB 310 310 39 19 9 53 33 26 9 32 XS60GB 305 305 39 05 9 50 32 97 9 25 XS60GB 315 S 315 39 33 9 56 33 55 9 39 XS60GB 310 S 310 39 19 9 53 33 26 9...

Page 5: ...d to be between 20 C and 46 C Celsius Maximum operating temperature range 40 C Celsius to 85 C 11 3 The minimum safe distance between the module and the module is recommended for 1 cm when the solar p...

Page 6: ...ring Each Motech module is factory equipped with two lengths of 4 0mm 2 UL Recognized PV Wire 90 C rated sunlight resistant Factory cables are terminated with UL TUV Recognized electrical connectors A...

Page 7: ...If hand cleaning is not possible pressure washer cleaning of module glass is permitted only when complying with all of the following restrictions 1 Cleaning fluid water at normal ambient temperature 2...