 1. INTRODUCTION 

 

The 

Motic

 SMZ-161 series stereomicroscopes are high performance Greenough design 

stereomicroscopes with continuous zoom ranges of 6:1. The microscopes in this series allow 

continuous variable magnification between 7.5X - 45X, while total magnification varies from 2.25X to 

180X depending on the eyepieces and auxiliary objectives used. With the bilateral zoom knobs, users 

are able to adjust magnification while the microscope remains perfectly parfocal. 

 

The SMZ-161 is the ideal instrument for examining objects of industrial, biological, medical or 

educational nature. 

 

SMZ-161 Standard Configuration and Parameters: 

For detailed specifications of the SMZ-161, please refer to the Appendix 1. 

 

Model Lens 

Tubes

Eyepieces 

Auxiliary 

Objectives 

Zoom 

factor

Magnification 

Working 

Distance 

SMZ-161B Binocular 

WF10X 

(Ø20) 

Optional 1:6  7.5X-45X  110mm 

SMZ-161T Trinocular 

 

There are two models in the series: the 

SMZ-161B

 which is equipped with a binocular system, and the 

SMZ-161T

 which is equipped with a trinocular system allowing for the attachment of CCD and digital 

camera devices. 

Summary of Contents for 1100201300082

Page 1: ...SMZ 161 Series Stereo Zoom Microscopes Instruction Manual...

Page 2: ...rements of modern research techniques and testing methods This involves modification to the mechanical structure and optical design of our instruments Therefore all descriptions and illustrations in t...

Page 3: ...ng Distance 6 3 4 Changing the Bulb 7 4 KNOWING YOUR MICROSCOPE 8 4 1 Stereo Body with Binocular or Trinocular Head 8 4 2 Stand 9 4 3 External Illuminator 9 4 4 Eyepieces and Auxiliary Objectives 10 4...

Page 4: ...remains perfectly parfocal The SMZ 161 is the ideal instrument for examining objects of industrial biological medical or educational nature SMZ 161 Standard Configuration and Parameters For detailed s...

Page 5: ...4 1 1 Nomenclature SMZ 161 R2GG R2LED Fig 1 SMZ 161 TP Fig 2...

Page 6: ...ertical post This is important as this collar keeps the microscope from sliding down the column 2 2 3 The head holder should rest on the support collar and both the head holder locking screw and the c...

Page 7: ...e focusing knob focus the sample using the highest magnification strength If the sample cannot be brought into focus adjust the height of the microscope along the column Remember to tighten the lockin...

Page 8: ...dule Screw the collector piece back in after changing the old one 3 4 3 For transmitted light turn the microscope over so that the bottom plate of the stand faces towards the user Remove the bottom pl...

Page 9: ...gnification is changed parfocal For adjustment procedures refer to section 3 2 of this manual The stereo body is mounted onto the circular mount of the head holder and is locked into place using the l...

Page 10: ...the bottom of the stand on the right hand side This knob governs the light intensity for the transmitted and incident lights The illuminating angle of the incident light can be adjusted using the scr...

Page 11: ...cluding 10X 15X and 20X Standard configuration is a pair of 10X eyepieces 4 4 2 To change the eyepieces unscrew the locking screw remove the original eyepieces replace with the new pair of eyepieces a...

Page 12: ...echniques in Bio Med applications including In situ silver gain staining and embryo observation Polarizing kit Must be used with transmitted light This kit including both a polarizer and analyzer is a...

Page 13: ...onnected to the microscope Select either the C mount or CS mount according to the CCD camera to be used Can only be used with the SMZ 161T Improved industrial boom stands With new slot groove design f...

Page 14: ...added to shield against dust and moisture 5 2 Protection against Water and Moisture The instrument should be kept away from all water sources including pipes and sinks Humidity in the room where the i...

Page 15: ...nds one hand holding the bottom of the stand and the other hand holding the top of the vertical post of the head holder of the microscope 5 4 4 The microscope should always be kept upright while movin...

Page 16: ...dapters 0 5X 0 65X 1X adapters available Auxiliary ESD objectives 0 3X WD 301 mm 0 5X WD 191 8 mm 0 63X WD 142 7 mm 0 75X WD 128 6 mm 1 5X WD 56 3 mm 2 0X WD 38 6 mm Max working distance with 0 3X aux...

Page 17: ...16...

Page 18: ...Tel 34 93 756 6286 Fax 34 93 756 6287 Website http www motic com E mail info speedfair com Motic China Group Ltd China Motic Building Torch Hi Tech Industrial Development Zone Xiamen P R C Tel 86 0592...

Reviews: