2.  UNPACKING AND ASSEMBLING THE MICROSCOPE 

 

2.1  Unpacking the Microscope 

The components for SMZ-161 stereomicroscopes are shipped integrative for protection. Open the 

styrofoam packing with care and do not leave any components attached to the packing being removed. 

Do not discard any of the packing materials until all of the components have been identified. If any 

damage occurs during transit, contact both the carrier and your supplier immediately. 

 

2.2  Assembling the Microscope 

2.2.1 

When handling the components, especially the optical parts, avoid touching any lens surfaces  

 

   

with bare hands or fingers as fingerprints and grease stains affect image quality. 

 

2.2.2 

After unpacking the stand, put it on a stable and flat table. Loosen the locking screw of the  

 

   

head holder, adjust the height of the head holder and lock the locking screw again. Make sure  

 

   

that the support collar is secured firmly below the head holder along the vertical post.  

 

   

This is important as this collar keeps the microscope from sliding down the column. 

 

2.2.3 

The head holder should rest on the support collar and both the head holder locking screw and  

 

   

the collar locking screw should be tightened.  

 

2.2.4 

Put the stereo body onto the head holder and lock it using the locking screw located on the  

 

   

right hand side of the head holder. To maintain the best stability, you are advised to lock the  

 

   

screw on the left hand side of the head holder as well. 

 

2.2.5  After removing the wrapping papers and packing materials around the eyepieces and other  

   optical 

parts 

(avoid 

touching 

the lens surfaces), carefully place the eyepieces into the eyepiece  

 

   

tubes and secure them using the locking screws. If necessary, loosen the locking screws before  

 

   

putting in the eyepieces. 

 

2.2.6 

Before turning on the power, plug the illumination power cord into the socket at the top of the  

 

   

column. Next, plug the power cord of the main frame into the local power supply. 

Note: before  

 

   

plugging in and turning on the power, make sure that the operation voltage of the  

 

   

microscope matches the voltage of the local power supply. 

 

 

Summary of Contents for 1100201300082

Page 1: ...SMZ 161 Series Stereo Zoom Microscopes Instruction Manual...

Page 2: ...rements of modern research techniques and testing methods This involves modification to the mechanical structure and optical design of our instruments Therefore all descriptions and illustrations in t...

Page 3: ...ng Distance 6 3 4 Changing the Bulb 7 4 KNOWING YOUR MICROSCOPE 8 4 1 Stereo Body with Binocular or Trinocular Head 8 4 2 Stand 9 4 3 External Illuminator 9 4 4 Eyepieces and Auxiliary Objectives 10 4...

Page 4: ...remains perfectly parfocal The SMZ 161 is the ideal instrument for examining objects of industrial biological medical or educational nature SMZ 161 Standard Configuration and Parameters For detailed s...

Page 5: ...4 1 1 Nomenclature SMZ 161 R2GG R2LED Fig 1 SMZ 161 TP Fig 2...

Page 6: ...ertical post This is important as this collar keeps the microscope from sliding down the column 2 2 3 The head holder should rest on the support collar and both the head holder locking screw and the c...

Page 7: ...e focusing knob focus the sample using the highest magnification strength If the sample cannot be brought into focus adjust the height of the microscope along the column Remember to tighten the lockin...

Page 8: ...dule Screw the collector piece back in after changing the old one 3 4 3 For transmitted light turn the microscope over so that the bottom plate of the stand faces towards the user Remove the bottom pl...

Page 9: ...gnification is changed parfocal For adjustment procedures refer to section 3 2 of this manual The stereo body is mounted onto the circular mount of the head holder and is locked into place using the l...

Page 10: ...the bottom of the stand on the right hand side This knob governs the light intensity for the transmitted and incident lights The illuminating angle of the incident light can be adjusted using the scr...

Page 11: ...cluding 10X 15X and 20X Standard configuration is a pair of 10X eyepieces 4 4 2 To change the eyepieces unscrew the locking screw remove the original eyepieces replace with the new pair of eyepieces a...

Page 12: ...echniques in Bio Med applications including In situ silver gain staining and embryo observation Polarizing kit Must be used with transmitted light This kit including both a polarizer and analyzer is a...

Page 13: ...onnected to the microscope Select either the C mount or CS mount according to the CCD camera to be used Can only be used with the SMZ 161T Improved industrial boom stands With new slot groove design f...

Page 14: ...added to shield against dust and moisture 5 2 Protection against Water and Moisture The instrument should be kept away from all water sources including pipes and sinks Humidity in the room where the i...

Page 15: ...nds one hand holding the bottom of the stand and the other hand holding the top of the vertical post of the head holder of the microscope 5 4 4 The microscope should always be kept upright while movin...

Page 16: ...dapters 0 5X 0 65X 1X adapters available Auxiliary ESD objectives 0 3X WD 301 mm 0 5X WD 191 8 mm 0 63X WD 142 7 mm 0 75X WD 128 6 mm 1 5X WD 56 3 mm 2 0X WD 38 6 mm Max working distance with 0 3X aux...

Page 17: ...16...

Page 18: ...Tel 34 93 756 6286 Fax 34 93 756 6287 Website http www motic com E mail info speedfair com Motic China Group Ltd China Motic Building Torch Hi Tech Industrial Development Zone Xiamen P R C Tel 86 0592...

Reviews: