background image

 

1

We are constantly endeavoring to improve our instruments and to adapt them to the requirements of 

modern research techniques and testing methods. This involves modification to the mechanical 

structure and optical design of our instruments.  

 

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are 

subject to change without notice.  

Summary of Contents for SMZ-161B

Page 1: ...SMZ 161 Series Stereo Zoom Microscopes Instruction Manual ...

Page 2: ...irements of modern research techniques and testing methods This involves modification to the mechanical structure and optical design of our instruments Therefore all descriptions and illustrations in this instruction manual including all specifications are subject to change without notice ...

Page 3: ...ing Distance 6 3 4 Changing the Bulb 7 4 KNOWING YOUR MICROSCOPE 8 4 1 Stereo Body with Binocular or Trinocular Head 8 4 2 Stand 9 4 3 External Illuminator 9 4 4 Eyepieces and Auxiliary Objectives 10 4 5 Other Accessories 11 5 CLEANING AND CARING FOR THE MICROSCOPE 13 5 1 Protection against Dust 13 5 2 Protection against Water and Moisture 13 5 3 Cleaning 13 5 4 Moving the Microscope 14 5 5 Electr...

Page 4: ...mains perfectly parfocal The SMZ 161 is the ideal instruments for examining objects of industrial biological medical or educational natures SMZ 161 Standard Configuration and Parameters Details please refer to the Appendix 1 SMZ 161 Specifications Model Eyepieces Auxiliary Objectives Zoom factor Magnification Working Distance Lens Tubes SMZ 161B WF10X Ø20 Optional 1 6 7 5X 45X 110mm Binocular SMZ ...

Page 5: ...4 1 1 Nomenclature SMZ 161 R2GG R2LED Fig 1 SMZ 161 BP Fig 2 ...

Page 6: ...vertical post This is important as this collar keeps the microscope from sliding down the column 2 2 3 The head holder should rest on the support collar and both the head holder locking screw and the collar locking screw should be tightened 2 2 4 Put the stereo body onto the head holder and lock it using the locking screw located on the right hand side of the head holder To maintain the best stabi...

Page 7: ...ng the focusing knob focus the sample using the highest magnification strength If the sample cannot be brought into focus adjust the height of the microscope along the column Remember to tighten the locking screw and support collar after adjusting the height of the microscope 3 2 2 Turn the zoom to the highest magnification Adjust the focusing knob until a clear and sharp image is obtained 3 2 3 T...

Page 8: ...le in Screw the collector piece back in after changing the old one 3 4 3 For transmitted light turn the microscope over so that the bottom plate of the stand faces towards the user Remove the bottom plate by unscrewing the four rubber feet For R2GG halogen stand remove the old light bulb from the socket and carefully plug the new light bulb in for R2LED stand unscrew the plank and remove the old L...

Page 9: ...gnification is changed parfocal For adjustment procedures refer to section 3 2 of this manual The stereo body is mounted onto the circular mount of the head holder and is locked into place using the locking screw on the right hand side of the holder While operating the microscope this locking screw should always be locked to maintain utmost stability 4 1 2 Binocular tube for the SMZ 161B The inter...

Page 10: ...ing the knob at the bottom of the stand on the right hand side This knob governs the light intensity for the transmitted and incident lights The illuminating angle of the incident light can be adjusted using the screw located behind the illuminator Besides the black and the white stage plate a frosted glass stage plate is provided for transmitted light This plate can be secured using the screw at ...

Page 11: ...and 20X Standard configuration is a pair of 10X eyepieces 4 4 2 To change the eyepieces unscrew the locking screw remove the original eyepieces replace with the new pair of eyepieces and secure the eyepieces using the locking screw 4 4 3 There are additional objectives of different magnifications to choose from including 0 3X 0 5X 0 63X 0 75X 1 5X and 2X Fig 3 Users are recommended to select addit...

Page 12: ...techniques in Bio Med applications including In situ silver gain staining and embryo observation Polarizing kit Must be used with transmitted light This kit including both a polarizer and analyzer is also placed onto the transmitted light outlet with the stage plate removed The sample can be placed between the polarizer and analyzer to perform polarized light microscopy Useful for analyzing jewelr...

Page 13: ...D camera or imaging device to be connected to the microscope Select either the C mount or CS mount according to the CCD camera to be used Can only be used with the SMZ 161T Improved industrial boom stands With New slot groove design for better locking microscope Grub screw locks into slot groove stopping tilt Microscope is positioned vertical to base with no slant Add position for hand carrying ar...

Page 14: ... added to shield against dust and moisture 5 2 Protection against Water and Moisture The instrument should be kept away from all water sources including pipes and sinks Humidity in the room where the instrument located should be kept as low as possible relative humidity should be kept below 70 It is recommended that optical components be kept in a dry box when not in use preferably with a desiccat...

Page 15: ...hands one hand holding the bottom of the stand and the other hand holding the top of the vertical post of the head holder of the microscope 5 4 4 The microscope should always be kept upright while moving 5 5 Electrical Parts of the Microscope 5 5 1 Before plugging the power cord into the power supply make sure that the supply voltage matches the operation voltage of the equipment 5 5 2 Turn the eq...

Page 16: ...standard 110mm Adapters 0 5X 0 65X 1X adapters available Auxiliary ESD objectives 0 3X WD 301 mm 0 5X WD 191 8 mm 0 63X WD 142 7 mm 0 75X WD 128 6 mm 1 5X WD 56 3 mm 2 0X WD 38 6 mm Max working distance 301mm Weight 3 5kg head with 1 0kg 3 7kg head with 1 2kg Optional illuminator Ring LED light fluorescent ring illuminator cold light source Stand option Plain stand Compact R2LED stand with 3W LED ...

Page 17: ...16 ...

Page 18: ...Tel 34 93 756 6286 Fax 34 93 756 6287 Website http www motic com E mail info speedfair com Motic China Group Ltd China Motic Building Torch Hi Tech Industrial Development Zone Xiamen P R C Tel 86 0592 562 7866 Fax 86 0592 562 7855 2000 2012 Motic China Group Co Ltd All rights reserved Motic is a registered trademark and service mark of Motic China Group Co Ltd Microsoft Windows logo is a registere...