The vehicle’s 12 V battery 
should be fully charged to get 
the best performance from your 
air compressor. If your vehicle’s 
battery is weak, the air 
compressor will not work at its 
maximum output level.

This appliance has a polarized 
plug (one blade is wider than 
the other), which fits in a 
polarized outlet only one way. If 
the plug does not fit fully in the 
outlet, reverse the plug. If it still 
does not fit, contact a qualified 
electrician to install the proper 
outlet. Do not change the plug in 
any way.

Operate in a safe work 
environment. Keep your work 
area clean and well lit. DO NOT 
expose the air compressor to 
rain or any other kind of bad 
weather. DO NOT use in damp 
or wet locations and DO NOT 
expose this tool to rain. Water 
entering a power tool will 
increase the risk of electric 
shock. DO NOT use in the 
presence of flammable gases or 
liquids.

Use only a two

-

wire extension cord 

that has a two

-

blade plug and a 

two

-

slot receptacle that will accept 

the plug on the product. Make 
sure your extension cord is in 
good condition. When using an 
extension cord, be sure to use 
one heavy enough to carry the 
current your product will draw. 
For lengths less than 6' (1.8 m) 
18 AWG extension cords should 
be used. An undersized cord will 
cause a drop in line voltage 
resulting in loss of power and 
overheating.

In a double

-

insulated product, 

two systems of insulation are 
provided instead of grounding. No 
grounding means is provided on a 
double

-

insulated product, nor 

should a means for grounding be 
added to the product. Servicing of 
a double

-

insulated product 

requires extreme care and 
knowledge of the system and 
should be done only by a qualified 
electrician. Replacement parts for 
a double

-

insulated product must 

be identical to those parts in the 
product.

Summary of Contents for 009-5097-2

Page 1: ...INSTRUCTION MANUAL model no 009 5097 2 DUAL POWER AIR COMPRESSOR IMPORTANT Please read this manual carefully before using this tool and keep it for future reference...

Page 2: ...maintenance advice Keep this instruction manual for future use Should this product be passed on to a third party this instruction manual must be included This MotoMaster product carries a three year...

Page 3: ...follow them while using this product TABLE OF CONTENTS Specifications 4 Safety 5 Introduction 5 Safety 6 Danger 6 Warning 7 Caution 8 Know Your Air Compressor 9 Preparation 9 Key Parts Diagram 11 Par...

Page 4: ...DC 12 V For use with 12 V DC power outlet only NOTE This unit is equipped with fuse protection If at some point the air compressor fails to operate when using the 12 V DC power method check the fuse...

Page 5: ...ates to PROTECTING PERSONAL SAFETY and PREVENTING EQUIPMENT PROBLEMS It is very important to read this manual carefully and understand it thoroughly before using the product The symbols listed below a...

Page 6: ...refers to a part number it refers to the parts list included Before allowing others to use this product make sure they are aware of all safety information DANGER Keep children away from the work area...

Page 7: ...ny ash residue or debris A dirty 12 V power outlet can cause the air compressor and power cord to overheat Overheating can cause damage to your air compressor vehicle and could cause bodily harm or in...

Page 8: ...lated Cluttered benches and dark areas increase the possibility of personal injury or property damage Allow air compressor to cool down for 10 minutes after each 10 minutes of continuous operation Aft...

Page 9: ...increase the risk of electric shock DO NOT use in the presence of flammable gases or liquids Use only a two wire extension cord that has a two blade plug and a two slot receptacle that will accept th...

Page 10: ...ulated product is marked with the words Double insulation or Double insulated The double insulation symbol may also be marked on the product Store unused equipment When not in use tools must be stored...

Page 11: ...KEY PARTS DIAGRAM 11 32 0 ACCESSORY COMPARTMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17...

Page 12: ...h 1 10 Quick connect valve adaptor 1 2 Increase decrease preset PSI level button 1 11 Presta valve adaptor 1 3 Digital pressure gauge 1 12 Sports needle 1 4 Run pause power switch 1 13 Mattress nozzle...

Page 13: ...Connect the quick connect valve adaptor 1 to the item that you are inflating and push the valve lock lever down to secure the connection fig B Push the power selector switch 1 in the top left corner...

Page 14: ...auge to set the desired PSI The preset range of the digital pressure gauge is between 3 and 120 PSI When the LCD readout screen is displaying the target PSI the LCD readout will blink three times at t...

Page 15: ...t you have programmed into the digital pressure gauge fig F To stop the air compressor before it reaches the preset PSI level push the run pause button 1 To resume inflation simply press the run pause...

Page 16: ...for automatic continuous power supply of 120 V current to the air compressor fig H Connect the quick connect valve adaptor 1 to the item that you are inflating and push the valve lock lever down to se...

Page 17: ...ed PSI The preset range of the digital pressure gauge is between 3 and 120 PSI When the LCD readout screen is displaying the target PSI the LCD readout will blink three times at the desired preset lev...

Page 18: ...reset PSI level that you have programmed into the digital pressure gauge fig M To stop the air compressor before it reaches the preset PSI level push the run pause button 1 To resume inflation simply...

Page 19: ...er DO NOT allow moisture or water to get into the interior moving parts Unplug the cord and disconnect from the power supply when the tool is not in use and store the unused tool to prevent rust The t...

Page 20: ...is below the actual pressure of the item that you are inflating 2 Cord is not plugged in 3 Circuit breaker is tripped 4 Fuse in 12 V DC power cord is blown 1 Adjust the preset pressure setting to hig...