background image

ALARM

POSSIBLE CAUSE

SOLUTION

ERROR SIGNAL

Overheat 

shutdown

The power inverter 

shuts down automatically if 

it exceeds its safe operating 

temperature.

• Switch the power inverter

off and disconnect it from 

the vehcle's 12 V outlet. 

• Disconnect all connected 

devices and allow the

power inverter to cool for at 

least 15 minutes.

• Use a brush to clear any 

blocked ventilation holes.

• Move the power inverter

to a cooler place. 

Reduce the load if 

continuous operation is 

required.

Red indicator 

light (G) turns on

PROBLEM

POSSIBLE CAUSE

SOLUTION

PROBLEM

POSSIBLE CAUSE

SOLUTION

The connected 
device does 
not switch on. 

The battery is defective.

Check the battery and replace it if required.

The power inverter is 
damaged and needs to be 
repaired.

Have the power inverter repaired by an 
authorized service centre. 

Incorrect connections to the 
inverter.

Check all connections. Make sure the 
connection is correct and tight.

The 
power inverter
will run some 
small loads, 
but not larger 
ones.

The cables are either too long or 
not heavy enough.

Only use the cables provided with your 
power inverter.

Measured 
power inverter
output 
is too low.

The battery voltage is too low.

Recharge the battery.

Battery 
run time is 
less than 
expected.

The AC product power 
consumption is higher than rated.

Use a larger battery to make up for the 
increase in power requirement.

The battery is old or defective.

Replace the battery.

The battery is not being charged 
properly.

Some chargers are not able to fully recharge 
a battery. Make sure that you use a powerful 
charger.

Power dissipation in DC cables.

Only use the cables provided with your 
power inverter.

No power to 
power inverter. Blown fuse.

Replace fuse.

Buzz in the 
audio system.

Inadequate internal power supply 
filtering of stereo system.

Use an audio system with a high-quality filter.

Television 
interference.

TV signals are weak.

• Adjust the orientation of the power inverter,

television, antenna and cables.

• Maximize TV signal strength by using a 

better antenna and use shielded antenna 
cable where possible. 

• Try a different TV model.

28

model no. 011-1870-6  |  contact us:  1-877-466-8191

29

TROUBLESHOOTING

TROUBLESHOOTING

Summary of Contents for 011-1870-6

Page 1: ... MANUAL SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and follow them with use of this product Questions Call Customer Service Hotline 1 877 466 8191 model no 011 1870 6 ...

Page 2: ...HNICAL SPECIFICATIONS 3 TECHNICAL SPECIFICATIONS SAFETY INFORMATION KEY PARTS DIAGRAM INTENDED USE Options for connecting devices to the power inverter OPERATION Determining the maximum load of connected devices Wattage of commonly used devices Before you start Connecting the power inverter Connecting the connector cables to the power inverter Connecting the power inverter to a 12 V outlet loads u...

Page 3: ... sure it will not get caught on moving parts of the engine When using car batteries always follow the advice from the manufacturer of the battery and in the vehicle instruction manual Using improper voltage may result in damage to the device and possible injury to the user The correct voltage is listed on the rating plate Never leave the device unattended during operation This manual contains info...

Page 4: ...damaged if connected to a battery with 16 V or more REVERSE POLARITY Power connections from a 12 V battery to the power inverter must be positive to positive and negative to negative A reverse polarity connection positive to negative will blow a fuse in the power inverter and might permanently damage the unit Damage caused by a reverse polarity connection is not covered by your warranty Disconnect...

Page 5: ...C CABLE WITH CLAMPS FOR DIRECT CONNECTION TO 12 V VEHICLE BATTERY H AC OUTLET A GREEN INDICATOR RED INDICATOR DC CABLE WITH 12 V OUTLET PLUG J 8 model no 011 1870 6 contact us 1 877 466 8191 9 KEY PARTS DIAGRAM KEY PARTS DIAGRAM ...

Page 6: ...hone digital camera portable work light portable DVD player battery charger stereo system laptop computer 13 TV soldering gun finishing sander 27 TV 3 8 drill 12 3 speed fan and other similar devices in automobiles boats tractors trucks and virtually anywhere else This power inverter uses a modified sine wave that delivers power consistent and efficient enough to run most devices adequately Option...

Page 7: ...t a device consumes continuously The SURGE STARTING WATTAGE is the amount of power that a device consumes at start up for a limited period of time 2 3 seconds Some devices e g induction motors of drills and fans may have a start up surge of 3 to 7 times the rated wattage IMPORTANT The power inverter can supply momentary surge power that is higher 600 W than its maximum power rating 300 W Some prod...

Page 8: ...ly DEVICE SURGE STARTING WATTAGE MAX 600 W RATED RUNNING WATTAGE MAX 300 W Light bulb 40 40 Table fan 400 200 Total wattage used 440 240 These devices usually CAN be connected to the power inverter These devices usually CANNOT be connected to the power inverter as they might have a start up surge or continuous rating that is too high 300 W Portable music MP3 player Digital Camera Smartphone Tablet...

Page 9: ...t exceeding 25 C 77 F WELL VENTILATED For proper cooling allow at least 2 5 cm of clearance around the power inverter CLEAN Choose a location that is free of any debris that could get into the power inverter SAFE Do not install the power inverter in a compartment with batteries or flammable liquids such as gasoline or explosive vapours Connecting the power inverter CAUTION Prior to connecting to t...

Page 10: ...ake sure that the respective holes are matching Screw the black cap back on the cabling terminal until the cable connector is tightly fixed POSITIVE RED CABLE CONNECTOR NEGATIVE BLACK CABLE CONNECTOR Connecting the power inverter to a 12 V outlet loads under 100 W Follow the instructions in the previous section Choose the DC cable with the 12 V outlet plug J See connecting the connector cables to ...

Page 11: ...metallic object wrench etc WARNING To prevent irritation and burns wear protective eyewear and clothing when you install the power inverter or work with a vehicle battery Should battery acid come into contact with skin or eyes flush it with water and consult your physician CAUTION Power connections from a 12 V battery to the power inverter must be POSITIVE RED TO POSITIVE AND NEGATIVE BLACK TO NEG...

Page 12: ...at the power inverter does not have to deliver the surge currents required for all the loads at once Set the on off switch H to the 0 position to switch off the power inverter CAUTION Switch the power inverter off and disconnect it from the power source when it is not in use IMPORTANT When the power inverter is switched off it draws no current from the battery When the power inverter is switched o...

Page 13: ...shutdown is about to occur See troubleshooting WARNING Before cleaning make sure the power inverter is switched off and disconnected from the power source The exterior of the device should be cleaned periodically with a damp cloth or sponge and a mild soap solution Be sure vents and fans are free of dust or debris Never immerse the device in water or any other liquid For cleaning never use corrosi...

Page 14: ...ry Red indicator light G turns on High Voltage shutdown A defective battery charging system can cause the battery voltage to rise to high levels 15 0 16 3 V Although the power inverter has a protection against high voltage it might still be damaged if the input voltage were to exceed 16 V Disconnect the connected devices Verify that the charging system is properly regulated and the battery is 12 V...

Page 15: ...er ones The cables are either too long or not heavy enough Only use the cables provided with your power inverter Measured power inverter output is too low The battery voltage is too low Recharge the battery Battery run time is less than expected The AC product power consumption is higher than rated Use a larger battery to make up for the increase in power requirement The battery is old or defectiv...

Page 16: ...efective part s repaired or replaced free of charge within the stated warranty period when returned by the original purchaser with proof of purchase This product is not guaranteed against wear or breakage due to misuse and or abuse Made in China Imported by MotoMaster Canada Toronto Canada M4S 2B8 30 model no 011 1870 6 contact us 1 877 466 8191 WARRANTY ...

Reviews: