CAUTION!
A) The connection is not fully inserted, leaving the copper rod visible.
B) The connection is not fixed in the locking position.
Connecting the power inverter to a 12 V outlet (loads under 100W)
• Follow the instructions in the previous section. Choose the quick connector cable with
12 V outlet plug (J) ( See connecting the connector cables to the power inverter).
The display in the 100 W section will glow blue, which means
the outlet can provide no more than 100 W of power. In the
event of overload, the power inverter will automatically
shut down.
• Plug the cable’s 12 V outlet plug into the 12 V outlet of your vehicle. Make sure the plug is fully inserted.
• The power inverter is now ready for use.
CAUTION!
Always disconnect the power cable from the vehicle's 12 V outlet when you are not using
the device.
Connecting the power inverter to a 12 V battery (loads up to 750 W)
Safety guidelines for handling batteries
DANGER!
A spark may be visible when making the connection to a battery because a current will flow
to charge the capacitors in the power inverter. Do not make this connection in the
presence of flammable fumes. Explosion or fire may result. Thoroughly ventilate the battery
compartment before making this connection.
DANGER!
Take special care when working with a car battery. Batteries contain corrosive materials and
present an
ELECTRIC SHOCK HAZARD.
DANGER!
Do not use the car battery in the proximity of open flames. Do not smoke when using a car
battery.
18
model no. 011-1901-4 | contact us: 1-877-466-8191
19
OPERATION
OPERATION