150W
100W
100W
100W
150W 150W
• Press the on /off button to toggle the display function.
• Switching off the power inverter: Press and hold the on/off button (G) until the digital
display (D) turns off.
CAUTION!
Disconnect the power inverter from the power source and switch off when it is not in use.
WARNING!
Use only the cables included with this inverter. Use of other cables may cause damage to the
inverter.
When the
power inverter is
switched on and
there is no load, all
four quadrants of
the display panel
are illuminated blue,
indicating 750 W are
available.
When power inverter
load is between 200 and
250 W, the blue light in the
750 W quadrant goes out,
indicating the largest load
should not exceed 500 W.
When power inverter
load is between 250 and
500 W, the blue light in the
500 W quadrant goes out,
indicating the total load
should not exceed 250 W.
When the
power inverter is
connected using the
12 V outlet plug,
the 100 W quadrant
is illuminated blue,
indicating the largest
load should not
exceed 100 W.
When power inverter
load is 750 W,
the blue lights in all
four quadrants go
out, indicating the power
inverter has reached
maximum load.
IMPORTANT!
When the power inverter is switched off, it draws no current from the battery. When the
power inverter is switched on without any load connected to it, the outlet draws
approx. 2.3 A from the battery. This low current draw will eventually discharge the battery.
Using the USB port
Plug the USB-powered device into the power inverter’s USB charging port and
operate normally.
IMPORTANT!
This unit’s USB charging port does not support data communication. It only provides
5 V / 2.1 A DC power to an external USB-powered device. Not all mobile phones are provided
with a charging cable. Data cables are not supported by this device. Please check with your
mobile phone dealer for the correct charging cable.
Automatic safety features
This power inverter includes the following automatic safety
features to ensure safe and trouble free operation:
• Vehicle battery low-voltage automatic alarm and shutdown is activated when the battery
voltage drops to 10–11 V, to protect the battery from being damaged.
• Vehicle battery high-voltage shutdown is activated when the battery voltage rises to a
dangerously high level due to a defective battery.
• Overload protection with automatic shutdown is activated when a device rated more than
750 W is plugged into the power inverter.
• Overheat protection with automatic alarm and shutdown is activated in case the power
inverter overheats due to improper ventilation or a high ambient temperature.
• Output short-circuit protection is activated in case of a short circuit in the connected
device.
• Built-in fan is activated when a significant amount of power increases the internal
temperature and it exceeds its ambient operating temperature.
• Replaceable 8 A fuse is used for continued protection against a risk of fire or electric
shock and should be replaced manually, if necessary.
An
AUDIBLE ALARM
warns you if a low-voltage shutdown is about to occur
( See troubleshooting).
22
model no. 011-1901-4 | contact us: 1-877-466-8191
23
OPERATION
OPERATION