background image

150W

100W

100W

100W

150W 150W

•  Press the on /off button to toggle the display function.

•  Switching off the power inverter: Press and hold the on/off button (G) until the digital 

display (D) turns off.

CAUTION!

Disconnect the power inverter from the power source and switch off when it is not in use.

WARNING!

Use only the cables included with this inverter. Use of other cables may cause damage to the 
inverter.

When the 
power inverter is 
switched on and 
there is no load, all 
four quadrants of 
the display panel 
are illuminated blue, 
indicating 750 W are 
available.

When power inverter 
load is between 200 and 
250 W, the blue light in the 
750 W quadrant goes out, 
indicating the largest load 
should not exceed 500 W. 
When power inverter 
load is between 250 and 
500 W, the blue light in the 
500 W quadrant goes out, 
indicating the total load 
should not exceed 250 W.

When the 
power inverter is 
connected using the 
12 V outlet plug, 
the 100 W quadrant 
is illuminated blue, 
indicating the largest 
load should not 
exceed 100 W.

When power inverter
load is 750 W, 
the blue lights in all 
four quadrants go 
out, indicating the power  
inverter has reached 
maximum load.

IMPORTANT!

When the power inverter is switched off, it draws no current from the battery. When the 

power inverter is switched on without any load connected to it, the outlet draws 

approx. 2.3 A from the battery. This low current draw will eventually discharge the battery.

Using the USB port

Plug the USB-powered device into the power inverter’s USB charging port and 

operate normally.

IMPORTANT!

This unit’s USB charging port does not support data communication. It only provides                

5 V / 2.1 A DC power to an external USB-powered device. Not all mobile phones are provided 

with a charging cable. Data cables are not supported by this device. Please check with your 

mobile phone dealer for the correct charging cable.

Automatic safety features

This power inverter includes the following automatic safety 

features to ensure safe and trouble free operation:
•  Vehicle battery low-voltage automatic alarm and shutdown is activated when the battery 

voltage drops to 10–11 V, to protect the battery from being damaged.

•  Vehicle battery high-voltage shutdown is activated when the battery voltage rises to a 

dangerously high level due to a defective battery.

•  Overload protection with automatic shutdown is activated when a device rated more than 

750 W is plugged into the power inverter.

•  Overheat protection with automatic alarm and shutdown is activated in case the power 

inverter overheats due to improper ventilation or a high ambient temperature.

•  Output short-circuit protection is activated in case of a short circuit in the connected 

device.

•  Built-in fan is activated when a significant amount of power increases the internal 

temperature and it exceeds its ambient operating temperature.

•  Replaceable 8 A fuse is used for continued protection against a risk of fire or electric 

shock and should be replaced manually, if necessary.

An 

AUDIBLE ALARM

 warns you if a low-voltage shutdown is about to occur 

 ( See troubleshooting).

22

model no. 011-1901-4  |  contact us:  1-877-466-8191

23

OPERATION

OPERATION

Summary of Contents for 011-1901-4

Page 1: ...UCTION MANUAL SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and follow them with use of this product Questions Call Customer Service Hotline 1 877 466 8191 model no 011 1901 4 ...

Page 2: ...h DC power source you will connect the power inverter to 750 TABLE OF CONTENTS 2 model no 011 1901 4 contact us 1 877 466 8191 QUICK START GUIDE 3 QUICK START GUIDE TECHNICAL SPECIFICATIONS SAFETY INFORMATION KEY PARTS DIAGRAM INTENDED USE Options for connecting devices to the power inverter OPERATION Determining the maximum load of connected devices Wattage of commonly used devices Before you sta...

Page 3: ...erter must be POSITIVE RED TO POSITIVE AND NEGATIVE BLACK TO NEGATIVE AC POWER AC output voltage nominal 115 V 60 Hz Maximum continuous AC output power 750 W Peak power 1500 W AC output frequency 60 1 Hz AC output waveform Modified sine wave DC POWER USB output 5 V 2 1 A max No load current draw at 12 V input 0 4 A Efficiency maximum 85 Low voltage alarm 10 5 11 0 V Low voltage shutdown 10 0 11 0 ...

Page 4: ...wer cable The device must be fastened so that it does not cause a safety hazard in case of collision or hard braking Route the power cable so that it does not interfere with the driver of the vehicle when plugged into the vehicle s 12 V outlet Prevent the power supply cable from hanging over sharp edges Using improper voltage may result in damage to the device and possible injury to the user The c...

Page 5: ...ter the engine has been switched off If the plug is left connected the vehicle battery might become discharged or damaged Using the device for extended periods of time can completely discharge the vehicle battery When using a power inverter continuously inside a vehicle that is not running the engine should be started at least once an hour for 10 15 minutes to keep the battery from discharging Do ...

Page 6: ...ke you have in your home This conversion process allows you to run standard household devices such as TVs VCRs portable stereos laptop computers and other similar devices in automobiles boats tractors trucks and virtually anywhere else OPTIONS FOR CONNECTING DEVICES TO THE POWER INVERTER According to the wattage of the devices and its features you can choose to connect the device to the or 12 V OU...

Page 7: ...rt up surge of 3 to 7 times the rated wattage IMPORTANT The power inverter can supply momentary surge power that is higher 1500 W than its maximum power rating 750 W Some products with a rated wattage lower than the maximum power rating for your power inverter may still exceed the power inverter s surge capability and trigger an overload shutdown Products rated with the following power and surge r...

Page 8: ...battery Owner s manual Check the power inverter s identification label to ensure that you have purchased the intended model and that it has the required specifications for its intended use Positioning of the power inverter Position the power inverter on a flat and stable surface in a location that is DRY Do not expose to water rain moisture snow or spray COOL Operate the power inverter in ambient ...

Page 9: ...hat you want to operate CAUTION Only use the cables provided with your power inverter Connect the cable with the DC cabling terminals B C on the back of the power inverter CAUTION Only use products provided by the 12 V outlet plug Make sure to connect the RED CABLE TO POSITIVE PORT and the BLACK CABLE TO NEGATIVE PORT Place the red cable connector on the positive DC cabling terminal red Make sure ...

Page 10: ...inverter is now ready for use CAUTION Always disconnect the power cable from the vehicle s 12 V outlet when you are not using the device Connecting the power inverter to a 12 V battery loads up to 750 W Safety guidelines for handling batteries DANGER A spark may be visible when making the connection to a battery because a current will flow to charge the capacitors in the power inverter Do not make...

Page 11: ...erter Fasten the POSITIVE RED CLAMP TO THE POSITIVE BATTERY POST and then fasten the NEGATIVE BLACK CLAMP TO THE NEGATIVE BATTERY POST Make a secure connection The power inverter is now ready for use CAUTION If you are going to disconnect the battery switch the power inverter off first See switching on off CAUTION Always disconnect the power cables from the car battery when you are not using the d...

Page 12: ...nto the power inverter s USB charging port and operate normally IMPORTANT This unit s USB charging port does not support data communication It only provides 5 V 2 1 A DC power to an external USB powered device Not all mobile phones are provided with a charging cable Data cables are not supported by this device Please check with your mobile phone dealer for the correct charging cable Automatic safe...

Page 13: ...charge level of the battery the battery capacity the amount of power drawn by the devices that are connected to the power inverter With an average load of about 750 W connected to the power inverter consider that you will have to start the vehicle regularly for example every hour or two to recharge the vehicle s battery Prior to doing so the power inverter must be disconnected from the power sourc...

Page 14: ...el The digital display D shows error codes when the power inverter has shut down due to the problems as shown in the following table PROTECTION POSSIBLE CAUSE SOLUTION ERROR CODE ON DISPLAY Low battery alarm As the battery discharges its voltage decreases Voltage drops to 10 5 11 0 V alarm Shut down sensitive loads such as computers and then recharge the battery Audible alarm red indicator Low vol...

Page 15: ...efective part s repaired or replaced free of charge within the stated warranty period when returned by the original purchaser with proof of purchase This product is not guaranteed against wear or breakage due to misuse and or abuse Made in China Imported by MotoMaster Canada Toronto Canada M4S 2B8 28 model no 011 1901 4 contact us 1 877 466 8191 WARRANTY ...

Reviews: