1. With the electronic functions turned off, place the level on a
horizontal surface where the bubble in the top vial is perfectly
centered. (FIG 1)
2. Press the On/Off button so that the tool beeps 3 times and the
top vial turns solid Green.
3. Press and hold the On/Off button approximately 5 seconds until
the top vial flashes RED and beeps once.
4. Turn level upside down and rest it on the same horizontal
surface. Wait for light to turn solid Green and beep 3 times.
(FIG 2)
5. Turn level right side up and rest on the same surface. The light
will remain solid Green and the tool will beep 3 times. The level
is now correctly calibrated for horizontal, diagonal and vertical
operation.
Note:
If the level is not calibrated correctly, the tool will continue
beeping, and the calibration procedure must be repeated.
7
16" LED Level
(MH-02-LL-B1-16-1)
(FIG 1)
(FIG 2)