background image

3A

3B

01

02

03

220mm

JAG400

JAG600

220mm

1040mm

1240mm

270mm

270mm

EN

EN

02. PACKAGE

03. OPERATOR

INSIDE PACKAGE

TECHNICAL SPECIFICATIONS

07

03

09

04

06

01

02

08

05

In the package you will find the following components:

01

 • 02 swing operators

02

 • 01 Control Board

03

 • 02 remote controls (4 channels) 

04

 • 02 Front supports

05

 • 02 Rear supports

06

 • 02 Capacitors [12,5µF (230V) or 35µF (110V)]

07

 • 01 Photocells

08

 • 01 User’s manual

09

 • Release keys

Electronic components in the kit:

Kit Package:

JAG

 specifications are as follow:

01

02

03

JAG400

JAG600

• Power Supply

230V 

230Vac 50/60Hz

230Vac 50/60Hz

110V

110Vac 50/60Hz

110Vac 50/60Hz

24V

24Vdc

24Vdc

• Power 

230/110V

300W

300W

24V

80W

80W

• Current

230V

1,3A

1,3A

110V

2,5A

2,5A

24V

3A

3A

• RPM

230/110V

1400 RPM

1400 RPM

24V

1650 RPM

1650 RPM

• Noise level

LpA <= 50dB (A)

LpA <= 50dB (A)

• Force

2800N

2800N

• Operating temperatures

-25°C a 75°C

-25°C a 75°C

• Thermal protection

120°C

120°C

• Protection class

IP54

IP54

• Working frequence

230/110V

25%

25%

24V

Intensive

Intensive

• Course

400mm

600mm

• Max leaf lenght

<5000mm

<6000mm

• Capacitor

230V

12,5µF

12,5µF

110V

35µF

35µF

Summary of Contents for JAG Series

Page 1: ...V4 1 REV 04 2018 JAG EN USER S AND INSTALLER S MANUAL...

Page 2: ...s marking on the product or literature indicates that the product andelectronicaccessories eg Charger USBcable electronicmaterial controls etc should not be disposed of as other household waste at the...

Page 3: ...product in an emergency and provide him the manual This device can be used by children 8 year old or older and persons whose physical sensory or mental capacities are reduced or by persons without ex...

Page 4: ...ic components in the kit Kit Package JAG specifications are as follow 01 02 03 JAG400 JAG600 Power Supply 230V 230Vac 50 60Hz 230Vac 50 60Hz 110V 110Vac 50 60Hz 110Vac 50 60Hz 24V 24Vdc 24Vdc Power 23...

Page 5: ...tical distance from the floor to the top of the front support Set dimension A this can be any size of your choice After you set dimension A subtract 20mm to find dimension B It is very important that...

Page 6: ...120 a 140 1295 1300 JAG 600 95 120 a 350 120 a 200 1695 1700 120 200 a 280 120 a 200 1695 1700 HORIZONTAL INSTALLATION DIMENSIONS EXTERIOR OPENING EXTERIOR INTERIOR Distance between the centers of the...

Page 7: ...be able to stretch retract arm easily see page 03B to get the correct position for supports Install the pins removed earlier on each side with a small amount of lubricant for less friction Unlock the...

Page 8: ...the gate to the open position 07 Loosen the screw shown in the image 24 so that it is possible to move the micro switch in the profile 08 Adjust the closure micro switch B until it makes click on the...

Page 9: ...tant to use mechanical stoppers in the opening and closing position of the gate If not respected components of the automation may suffer efforts for which they were not prepared and as a result will b...

Page 10: ...n the micro s If it does not operate replace with a new 24V engine and re test to ensure that all is ok To detect which are the components with problems in a 24V JAG automatism installation it is nece...

Page 11: ...or Motor Motor Motor Black Black Gray Gray Brown Brown COM COM Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply AUTOMATION AUTOMATION Ground Wire Ground Wire Ground Wire G...

Page 12: ...cloth remove the ex cess leaving a homogeneous layer of lubri cant over the arm Place a small amount of lubricant on the holes that contains support pins Check motor supports Make sure that supports r...

Page 13: ...board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motors doesn t work remove them from installation site and send to our MOTORLINE technical services for diagnos...

Reviews: