12A
12B
17.A
17
11
C
C
10mm
11
12
15
12.A
B
B
B
B
B
B
B
B
B
A
B
A
B
14
EN
EN
11.
Also on the ground, touch the glass (with the gripper already on place) to the safe. Take
the full measure of the glass lower limit to the upper limit of the safe. Keep
Full Measure A
Safe
upper
limit
Glass
inferior
limit
17.
Refit the safe in the wall and apply the most suitable fixing to the surface that will.
14.
Put the safe against the wall and, using scriber materal, do the markings on the exact
locations where the safe was pierced. Keep attention to the safe leveling when you make the
markings.
15.
Make holes with xmm in the locations
marked on the wall.
16.
Put the fixing profile back on the wall and
apply the fixative indicated to the surface
that will receive it (see table below).
Review the cleaning of the operator.
04. INSTALLATION
04. INSTALLATION
SAFE INSTALLATION
SAFE INSTALLATION
12.
Transport and center the full measure to the location where it will be applied to door
using a scriber material. Add 10mm to the full extent, leaving a margin so that the glass does
not touch the floor. Make at least two marks, bearing in mind the leveling of the automation.
13.
Make holes in the safe. The holes on the limits of the safe must be diverted 50mm from
the safe's lateral tops if possible, while the remaining holes should be between 350 and 400
mm apart. The holes bust be made in the area indicated on the image.
Please be aware of the released swarfs during drilling. These should be removed
from within the automation to avoid damaging / conditioning the operation of the
components.
Floor
10mm
Full Measure
+
10mm
Passage
zone
Passage
zone
Bucha
Surface
Fixation
Concrete/Stone
Plastic Bushing
Concrete/Stone
Metallic Bushing
Surface
Fixation
Brick
Chemical Bushing
Metal
Self-Drilling Screw
Furo
Parafuso
A.
50mm
B.
350 a 400mm