04. INSTALLATION
04. INSTALLATION
STOPPERS ADJUSTMENT
GUIDES INSTALLATION
28.
Take the measurement between the glass
and the upper part of the glass (under the
gripper).
29.
Take the same measurement to the glass's
lower limit.
WALL
FLOOR
FLOOR
FLOOR
FLOOR
Measure x
30.
Now place the guide (without frontal
cover) on the glass and align it by the wall
limit.
31.
Do the markings, remove the guide
and drill it with an appropriate size for the
purpose.
32.
Put the plastic plugs, put the guide and
fasten with suitable screws, leaving a gap of
1mm between the glass and the guide (32.A).
You can also adjust this space in 5mm.
33.
Refit the cap and repeat this procedure for
the other side.
34 and 35.
Make a complete manual opening to check for obstacles during opening / closing
and if the course is fully made. If it doesn't, adjust the stoppers position inside the safe. Uns-
crew slightly the two screws (30) and move the stopper to the desired location.
ATTENTION:
Make sure that the door never
leaves the guide in fully open and closed
position. To do so, the glass must overlap
between 30 to 40mm (min).
One leaf door - 2 stoppers
Two leaves door - 2 stoppers
Closing stopper
Closing stopper
Opening stopper
Opening stopper
• STOPPERS LOCATION