05. PROGRAMMING
CONTROL BOARD
05. PROGRAMMING
CONTROL BOARD
The parameters selected in the control device are available after the door makes a fully open
and close maneuver (path recognition).
Have the full sense of the weight and the measurements of the door you want to program
because the sensitivity must be adjusted according with them.
When adjusting the sensitivity, it is also necessary to adjust the speed in order to prevent the
door to detect obstacles and thus presents a continuous movement.
CONTROL BOARD DESCRIPTION
A
Indication LED
It indicates the control board's power supply.
B
Start button
After pressing this button, the door will open.
C
Adjust door opening
speed
When rotating from the right to the left, it will decrease
the door's opening speed. If your turn from the left to the
right, it will increase.
The speed can be adjusted from 300 to 550 mm/s.
D
Adjust door closing
speed
When rotating from the right to the left, it will decrease
the door's closing speed. If your turn from the left to the
right, it will increase.
The speed can be adjusted from 300 to 550 mm/s.
E
Pause time
adjustment
If you turn from right to left, it will decrease the time
the door waits from the point it opens up to a new
recognition before closing. If you turn from left to right,
it will increase. It can be adjusted between 0 and 20 sec.
F
Reverse sensitivity
adjustment
If you rotate from right to left, it will increase the sensiti-
vity of the door. If you rotate from left to right, it will de-
crease. If you decrease the sensitivity excessively, it may
cause accidents or failures in the motor.
Their characteristics are as follows:
•
PRE-PROGRAMMING CAUTIONS
•
DESCRIPTION
•
CONTROL BOARD CONNECTORS DESCRIPTION
LATERAL A
LATERAL B
FRONTAL VIEW
CENTRAL DIPPERS DESCRIPTION
K1
ON
Activates the output of power to the motor, allowing the selected operation
of k4.
OFF
Disables the output of power to the motor, defined on k4.
K2
ON
In case of power failure, the door remains closed.
OFF
In case of power failure, emergency batteries keep the door open. The door
will open continuously until the power does not return. It works on all se-
lector functions except for doors with the selector with "LOCK" the function
ON, with an electric lock installed.
K3
ON
Opening a leaf to the left.
OFF
Double opening or opening one leaf to the right.
K4
ON
More strength in the closing maneuver to the mechanical anti-panic system mode.
OFF
Standard 2V output to keep the door closed.