background image

4A

4B

01•

02•

03•

04•

05•

06•

07•

08•

09•

10•

EN

EN

KVM105, KVM110 and KVM115

 are spindle drive automatims for sectional industrial door automation, 

with the possibility of horizontal or vertical application. The ease of installation,

configuration and maintenance make it ideal for all sectional doors.

The automatism release system allows the user to open 

manually, in case of emergency and/or power cuts.

For that just have to pull the circular chain in one direction 

or another to proceed to the

manual opening or closing as shown in the picture.

In the kit you will find the following components:

02. AUTOMATISM

02. AUTOMATISM

KVM105, KVM110 AND KVM115

KVM105

KVM110

KVM115

• Lubricant Type

Oil

• Noise

<55dB

• Chain Type

Standard chain

• Maximum limit of limit switches

20 motor's rotations

• Shaft Bore Diameter

Ø25,4mm

• Working temperature

-20~+45°C

• IP

IP54

• Power Supply

230V 50 Hz

400V 50 Hz

• Capacitor

35µF

39µF

-

• Power

650W

700W

800W

• Force

70N

120N

200N

• Working frequency

25%

20%

• Thermal

120°C

• Motor RPM

1400 RPM

• Reducer RPM 

24 RPM

• Weight

20Kg

20,2Kg

20,7Kg

TECHNICAL CHARACTERISTICS

MANUAL OPENING / CLOSING

PACKAGE

01

• 01 KVM Motor 

02

• 01 Control panel (with control board)

03

• 01 Motor fixing plate

04

• 01 Chain

05

• 02 Protection ring

06

• 04 Motor fixing screws

07

• 01 Dowel

08

• 01 Cable Entry Sleeves

09

• 01 Release System

10

• 01 Shaft Reducer

Summary of Contents for KVM105

Page 1: ...v5 1 REV 07 2021 KVM105 KVM110 KVM115 KVM105 KVM110 KVM115 EN INSTALLER AND USER S MANUAL...

Page 2: ...ble electronic material controls etc should not be disposed of as other household waste at the end of its useful life To avoid possible harm to the environment or human health resulting from the uncon...

Page 3: ...with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorize...

Page 4: ...esanyrepairormodification unlocktheautomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the ma...

Page 5: ...l find the following components 02 AUTOMATISM 02 AUTOMATISM KVM105 KVM110 AND KVM115 KVM105 KVM110 KVM115 Lubricant Type Oil Noise 55dB Chain Type Standard chain Maximum limit of limit switches 20 mot...

Page 6: ...b x c 400x236x110 450x300x200 450x240x110 Reducer Width c 110 110 110 Total Motor Height a 400 450 450 Control Panel Dimensions d x e x f 170x200x100 Motor Depth b 236 240 240 Total Height of Electro...

Page 7: ...d make the drills to fixate the motor ATTACH MOTOR Fix the plate on the wall and then fix it in the motor Put the protection ring on the vain touch it to the motor and and tighten AUTOMATISM INSTALLAT...

Page 8: ...ick Turn to tighten the screw Make sure the door is open and make sure about which is the opening limit switch General tuning is for full tuning looping tuning rings Fine tuning is in turn a detailed...

Page 9: ...4 INSTALLATION MAP INSTALLATION GUIDE 1500mm Control Panel with control board KVM105 KVM110 KVM115 Motor You can install the engine horizontally or vertically the procedure is the same See detail A DE...