7A
7B
1
4
3
3
2
click
1
2
4
5
3
5
3
2
1
EN
EN
03. INSTALLATION
03. INSTALLATION
FIX CONTROL PANEL ON THE WALL
ADJUSTMENT OF LIMIT SWITCHES
1
3
MARK THE HOLES
Make a wall mark to a distance of 1500mm from the floor.
Put the base of the board box in the marking. Marks the drilling locals.
DRILL THE HOLES
Then proceed to the drillings.
ATTACH CONTROL BOARD
Apply the bushings and fix the board on the wall.
CONNECT CONTROL BOARD
Insert the wires through inferior side of the board box. Put the box cover.
Close the cover and press the screws until the box is completely fixed.
Loose the screw
A
opening
micro (right ring) and
adjust the ring until you
hear the micro click. Turn
to tighten the screw.
Make sure the door is open and make sure
about which is the opening limit-switch.
General tuning
is for full tuning, looping
tuning rings.
Fine tuning
is in turn a detailed tuning on
the tuning ring to achieve the most accurate
tuning.
Make sure the door is closes and repeat the 2 and 3 processes (middle ring).
Use now screw
B
to a more
precisely tuner of the limit-
switch, tuning the plastic
that active the micro.
On the last micro make an identical
tuning on the opening micro so that it can
be activated just before the opening finish.
Screw A correspondes to general tuning and B is the fine tuning screw.
Do not only use fine tuning if you want make a full adjustment, this may damage the
tuning rings.
If the motor operates in the opposite
direction, you must change the
connections that turn on the motor,
inside the industrial box.