background image

3A

3B

EN

EN

01. SAFETY INSTRUCTIONS

01. SAFETY INSTRUCTIONS

STANDARDS TO FOLLOW

STANDARDS TO FOLLOW

• It is important for your safety that these instructions are followed.

• Keep these instructions in a safe place for future reference.

• The 

ELECTROCELOS S.A.

 is not responsible for the improper use of the 

product, or other use than that for which it was

designed.

• The 

ELECTROCELOS S.A.

 is not responsible if safety standards were not 

taken into account when installing the

equipment, or for any deformation that may occur.

• The 

ELECTROCELOS S.A.

 is not responsible for insecurity and malfunction 

of the product when used with components

that were not sold by the them.

• This product was designed and manufactured strictly for the use 

indicated in this manual.

• Any other use not expressly indicated may damage the product and/or 

can cause physical and property damages, and

will void the warranty.

• Do not make any changes to the automation components and/or their 

accessories.

• Keep remote controls away from children, to prevent the automated 

system from being activated involuntarily.

• The customer shall not, under any circumstances, attempt to repair or 

tune the automatism. Must call qualified

technician only.

• The installer must have certified professional knowledge at the level of 

mechanical assemblies in doors and gates

and control board programmation. He should also be able to perform 

electrical connections in compliance with all

applicable regulations.

• The installer should inform the customer how to handle the product in 

an emergency and provide him the manual.

This product is certified in accordance with European 

Community (EC) safety standards.

This product complies with Directive 2011/65/EU of the 

European Parliament and of the Council, of 8 June 2011, on 

the restriction of the use of certain hazardous substances in 

electrical and electronic equipment

(Applicable in countries with recycling systems).

This marking on the product or literature indicates that the 

product and electronic accessories (eg. Charger, USB cable, 

electronic material, controls, etc.) should not be disposed of 

as other household waste at the end of its useful life. To avoid 

possible harm to the environment or human health resulting 

from the uncontrolled disposal of waste, separate these items 

from other types of waste and recycle them responsibly to 

promote the sustainable reuse of material resources.Home 

users should contact the dealer where they purchased this 

product or the Environment Agency for details on where 

and how they can take these items for environmentally safe 

recycling. Business users should contact their vendor and 

check the terms and conditions of the purchase agreement. 

This product and its electronic accessories should not be mixed 

with other commercial waste.

This marking indicates that the product and electronic 

accessories (eg. charger, USB cable, electronic

material, controls, etc.) are susceptible to electric shock by 

direct or indirect contact with electricity. Be

cautious when handling the product and observe all safety 

procedures in this manual.

Summary of Contents for M1805

Page 1: ...V4 0 REV 10 2018 M1805 EN USER INSTALLER MANUAL ...

Page 2: ... SCHEMES TECHNICAL CHARACTERISTICS 03 THE AUTOMATION INSTALLATION MEASURES OPENING DIRECTION 04 PRE INSTALLATION INSTALLATION PROCESS 05 INSTALLATION TECHNICAL CHARACTERISTICS PROGRAMMING 06 THE CONTROL BOARD INSTRUCTIONS FOR FINAL CONSUMERS INSTRUCTIONS FOR SPECIALIZED INSTALLERS 07 TROUBLESHOOTING INDEX RADARS AND PROGRAM SELECTOR CONNECTION 8B 8B 3A 4 6 7 8A 9A 10A 11A 11B 12 12 5 ...

Page 3: ...pplicable regulations The installer should inform the customer how to handle the product in an emergency and provide him the manual This product is certified in accordance with European Community EC safety standards This product complies with Directive 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical...

Page 4: ...1 Radar CR10MS CR10MS Jumper N C Jumper N O FOTO9S1A Photocells closure 11 12 If you do not use photocells place a shunt between 11 12 inputs FOTO9S1A Photocells open Control board Electric lock magnetic lock 24V continuous power output Battery 24V M1805 Automatism M1601 Radar 12V 12V The electro lock current can not exceed 600mA All connections should be made with the power supply disconnected ...

Page 5: ... 1 6 7 8 9 10 11 12 13 14 15 2 3 4 K1 K2 5 EN 02 CONNECTION SCHEMES RADARS AND PROGRAM SELECTOR CONNECTION Control board Control board PROGRAM SELECTOR EXTERNAL Radar M1601 INTERNAL Radar M1601 red white purple orange green green white white yellow yellow brown brown green black ...

Page 6: ... singular doors with interlocking connected to each other you should be aware these connections Only when one of the doors is closed the other can open When using this function if one of the doors is disconnected from the electric current the other will not open Control board of the 1st door 1st door is closed 2nd door started opening Control board of the 2nd door All connections should be made wi...

Page 7: ...iometer nº4 on the leaf nº2 control board from to create a delay relati ve to the leaf nº1 Operation When using a door with two leaves you should note these connections This function will allow the two sheets work in a coordinated manner All connections must be made with the power supply disconnected In this function if the leaf nº2 encounters an obstacle during closure the micro will give opening...

Page 8: ...or external opening Ângulo de abertura 0 110 Opening speed 90 2 sec 4 sec Closing speed 90 2 sec 4 sec Pause time in opening 1 sec 20 sec Manual strength 30N Consumption 50W Operating temperature 20 Ϲ 50 Ϲ Door s maximum weight 100kg Accessories output 500mA Eletric lock output 600mA 03 THE AUTOMATION 105mm 75mm 554mm 676mm 516mm 0 20 40 60 80 100 600 700 800 900 1000 1100 1200 Door maximum weight...

Page 9: ... 112 16 125 106 676 76 100 75 77 X 30 30 MAX 60 516 04 PRE INSTALLATION INSTALLATION MEASURES OPENING DIRECTION 04 PRE INSTALLATION INSTALLATION MEASURES OPENING DIRECTION Opening orientation LEFT Opening direction INSIDE Opening orientation RIGHT Opening direction INSIDE Opening orientation LEFT Opening direction OUTSIDE Opening orientation RIGHT Opening direction OUTSIDE ...

Page 10: ...fixation plate 08 Slide the automation to the right and se cure it with the 6 screws 02 Remove the 6 screws which hold the au tomation to the wall fixation plate 10 Secure the arm on the automation and set the correct position of the guide to fix it in the door 04 Put the plate against the wall and make the markings pay attention the measures 11 Move the door manually to set the position of the op...

Page 11: ...necting to the eletric current check if there is some sort of obstacle that hinders the normal operation of the door and if the stopper is well placed 03 Put the K2 and the K1 in the desired position according to the dipper board from the page 11A 04 Turn on the electric current The door will have the following behavior Slowy closes Slowly opens Closes to memorise the position and stays in normal ...

Page 12: ...s 2 Check if any of the door control devices key selector and push button are locked and are sending permanent signal to the control board 3 Consult a qualified MOTORLINE technician A SAFETY SYSTEMS Security systems are opened 1 Close with a shunt all control board safety systems N C contacts If the automatism starts to work normally analyze which are the problematic devices 2 Remove one shunt at ...