16A
16B
EN
EN
PROGRAMMING MENU - 04
PROGRAMMING MENU - 04
06. DESCRIPTIONS
06. DESCRIPTIONS
Parameter
Function
Settings
Factory Setting
04.00
OPEN SPEED
Allows set door opening speed.
00.00 to 70.00 Hz
50.00 to 70.00 Hz
04.01
CLOSE SPEED
Allows set door closing speed.
00.00 to 60.00 Hz
30.00 to 40.00 Hz
04.02
OPENING DECELERATION SPEED
Allows you to select the deceleration speed on the ascent.
NOTE
•
The changes on deceleration opening or closing speed will
change the length of the deceleration.
00.00 to 40.00 Hz
25.00 Hz
04.03
CLOSING DECELERATION SPEED
Allows you to select the deceleration speed on the descent.
NOTE
•
If change the door speed it is necessary adjust this parameter.
00.00 to 40.00 Hz
25.00 Hz
04.50
LENGHT OPENING DECELERATION
Allows to set the lenght of deceleration. The lenght can be set in
course programming or in the menu diretly.
0 to 1000
150
(250mm)
04.51
LENGHT CLOSING DECELERATION
Allows to set the lenght of deceleration. The lenght can be set in
course programming or in the menu diretly.
0 to 1000
150
(250mm)
04.52
PAUSE TIME
Allow to set the time the door is paused when it is open.
NOTE
•
By set 0 seconds, the door has no pause time.
0 = OFF
0 to 99
(ex: 99=99 sec.)
5s
04.53
HUMAN PRESENCE
This menu allows the door to open with an impulse until it reaches
the limit switch.
In order to close the door the user must be permanently pressing the
door down button.
In this function the pedestrian button will be descent.
0 = Disabled
1 = Enabled
0 = Disabled
04.54
OP-CH/PED BUTTON LOGIC
This menu allows to add 3 working modes each with their
specifications.
0 = Step by step
1 = Condominium
2 = Inversion
1 = Step by step
04.55
ACCELERATION RAMP AT OPENING
This menu allows you to adjust the opening acceleration ramp time
to allow a smoother start of the door.
0 to 30
(ex: 10=1 sec.)
15
04.56
ACCELERATION RAMP AT CLOSING
This menu allows you to adjust the closing acceleration ramp time to
allow a smoother start of the door.
0 to 30
(ex: 10=1 sec.)
15
Parameter
Function
Settings
Factory Setting
04.57
PEDESTRIAN OPENING TIME
This menu can select the lenght of the pedestrian opening. Knowing
that 100 means 8M if put 12 means opening of a meter. If the Human
presence is active this menu doesn't work. If set to 0 the CH/PED
button will only be closed.
0 to 100
15
(aprox. 1.5m)
04.58
DECELERATION RAMP AT INVERSION
Allows to set the deceleration time at inversion. Steeper or smoother
stop.
0 to 20
(ex: 10=1 sec.)
10
(1 s)
04.59
04.60
MANEUVERS COUNT
This function allows to view all complete maneuvers performed by
the automation.
The menu 04.60 show the number of maneuvers performed to the
thousands while the menu 04.59 show up to hundreds of thousands
(see example).
04.61
FLASHING LIGHT OUTPUT
Allows to change the operating logic of flashing light. If it is set to 0 the
flashing light will be active only when the motor is working. If select
1 the flashing light is active as long as it exits the closing limit switch,
when it reaches the closing limit switch it will remain ON for the time
set in menu 04.63.
0 = connected
in opening and
closing
1 = courtesy light
0 = opening and
closing
04.62
RESET MANEUVER COUNT
This menu allows to reset the maneuvers of menus 04.59 and
04.60. In order to be able to reset, will need to enter the password
available only to the Motorline technical department.
Password must be entered
04.63
COURTESY LIGHT TIME
This menu allows adjust the time when the light is on, since
reaching the limit switch if selected in menu 04.61.
0 to 50 Min
0
04.64
PROGRAMMING MENU
This menu has the function of placing the control board in course
programming.
0 to 1
1 = control board
in programming
04.65
REVERSE SLOWDOWN ADJUSTMENT
This menu allows you to adjust the inversion slowdown. When the
door movement is reversed, the slowdown may be higher or lower
than the reference value. Therefore, with this menu you can adjust
to the desired value.
0 to 1000
150
Menu 04.59
Total maneuvers = 20502
Notes:
1 maneuver = 1 opening
and closing cycle.
Example:
Menu 04.60
If the values are incorrectly adjusted, there is a risk of damage to the motor and inverter.