7A
7B
3s
6A
6B
EN
EN
Opening Ramp
Set the position of the ramp
and its duration.
Closing Ramp
Sets the position of the ramp
and its duration.
(
Factory default
dA 3; dF 3
)
This menu allows you to set the barrier's working time.
During the automatic programming, the barrier performs the following maneuvers:
1º
if it is open, closes with deceleration
2º
opens normally
3º
closes normally
To carry out this programming is necessary that the limit switches are duly installed.
03
• Appears a
circular motion on
the display indicating
that the automatic
setting is in progress.
01
• Press MENU for 3
seconds.
02
• P0 appears.
Press MENU for 3
seconds.
04
• When P1 appears,
the automatic
programming is
over. If you want to
program P1, continue
in step 03 from P1
menu. To exit the
programming press
↑↓
simultaneously.
01
• Press MENU for 3
seconds.
min.
max.
0s
COURSE AUTOMATIC PROGRAMMING
04. PROGRAMMING "P"
RAMP ADJUSTMENT
04. PROGRAMMING "P"
9s
02
• P0 appears.
Press ↓ once.
03
• P1 appears.
Press MENU for 3
seconds.
06
• dF appears.
Press MENU for 3 seconds.
NOTE
•
The function allows you to adjust
the ramp in the opening. It is necessary
to adjust the value so that the boom has
a correct slowdown until reaching the
limit-switch.
04
• dA appears.
Press MENU for 3 seconds.
NOTE
•
The function allows you to adjust
the ramp in the opening. It is necessary
to adjust the value so that the boom has
a correct slowdown until reaching the
limit-switch.
05
• The ramp set by factory appears. If
desired, change the ramp between 0 and
9, by using ↑↓.
07
• The ramp set by factory appears. If
desired, change the ramp between 0 and
9, by using ↑↓.
08
• P2 appears.
To program P2, continue in step 3 from P2 menu (page 7A).
To exit the programming press ↑↓ simultaneously.
Normal
speed
Ramp
Normal
speed
Ramp