12A
12B
11A
11B
EN
EN
06
• P8 appears.
To program P8, continue in step 3 from P8 menu (page 11B).
To exit the programming press ↓↑ simultaneously.
06
• P9 appears.
To program P9, continue in step 3 from P9 menu (page 12A).
To exit the programming press ↓↑ simultaneously.
FLASHING LIGHT
This menu allows you to set the gate's operating mode.
Functioning in automatic
mode
1st
impulse -
OPENS
2nd
impulse -
STOPS,
TIMER AND CLOSES
(IF P4>00)
3rd
impulse -
INVERTS
Functioning in step by
step mode
1st
impulse -
OPENS
2nd
impulse -
STOPS
3rd
impulse -
CLOSES
4th
impulse -
STOPS
If is fully open and timed,
the gate closes
Functioning in
condominium
mode
Does not accept orders
during opening and
pause time, in closure
it reverses (either by
transmitter or control
board start button)
factory default (
00
)
02
• P0 appears.
Press ↓ seven times.
01
• Press MENU for 3
seconds.
03
• P7 appears.
Press MENU for 1
second.
05
• Press MENU to
save the defined
function.
04
• Appears the
function currently set.
If you want, change
the function to 00, 01
or 02, using
↓↑.
04
• Appears the
function currently set.
If you want, change
the function to 00, 01
or 02, using ↓↑.
OPERATING LOGIC
Intermittent
(opening and closing)
During the gate's
opening/closing
movement, the
flashing light will
work intermittently.
During movement
of
the gate (opening and
closing), the flashing
light will remain lit.
Courtesy light
During operation it
converts the firefly
output into courtesy
light according to the
time defined in E2.
(p.13B).
Factory defaut (
00
)
01
• Press MENU for 3
seconds.
02
• P0 appears.
Press ↓ eight times.
03
• P8 appears.
Press MENU for 1
second.
05
• Press MENU to
save the defined
function.
04. PROGRAMMING "P"
04. PROGRAMMING "P"