• Power supply

230V AC  50-60Hz

• Lightbulb’s output

230V AC 50Hz 100W max.

• RGB Lightbulb’s output

24V DC 100mA max.

• Motor’s output

230V AC  50-60Hz  1000 W max.

• Auxiliary accessories output

24V DC  8 W max.

• Security and BT transmitters

24V DC

• Working temperature

-25°C to + 55°C

• Incorporated Radio Receptor

433,92 Mhz

• OP Transmitters

12bits or Rolling Code

• Maximum Memory Capacity

100 (full opening) - 100 (pedestrian opening)

• Control board Dimensions

105x130 mm.

The MC50SC is a monophasic control board com a control system via incorporated rádio,

developed for the automation of sliding gates.

CN1

01

 • Grounding

02

 • Grounding

03

 • 230V Line Input (phase)

04

 • 230V Line Input (neutral)

05

 • 230V Motor’s Output – Opening

06

 • 230V Motor’s Output – Common

07 

• 230V Motor’s Output - Closing

08

 • AC 230V Lightbulb Output 

09

 • AC 230V Lightbulb Output 

CN2

01

 • Pedestrian Push input

02

 • Total Push input

03

 • Motor’s opening limit-switch input (OPEN)

04

 • Motor’s closing limit-switch input (CLOSE)

05

 • Common

CN3

01

 • 24V DC 200mA max power supply 24V

02

 • 24V DC 200mA max power supply (    )

• CONNECTOR’S DESCRIPTION

TECHNICAL SPECIFICATIONS

02. THE CONTROL BOARD

STANDARDS TO FOLLOW

01. 

SAFETY INSTRUCTIONS

• It is important for your safety that these instructions are followed.

• Keep these instructions in a safe place for future reference.

• The 

ELECTROCELOS S.A.

 is not responsible for the improper use of the product, or other use than that for which 

it was designed.

• The 

ELECTROCELOS S.A.

 is not responsible if safety standards were not taken into account when installing the 

equipment, or for any deformation that may occur.

• The 

ELECTROCELOS S.A.

 is not responsible for insecurity and malfunction of the product when used with 

components that were not sold by the them.

• This product was designed and manufactured strictly for the use indicated in this manual.

• This control board is not appropriate for inflammable or explosive environments.

• Any other use not expressly indicated may damage the product and/or can cause physical and property damages, 

and will void the warranty.

• Do not make any changes to the automation components and/or their accessories.

• Control board for indoor use with 230V connection.

• Keep remote controls away from children, to prevent the automated system from being activated involuntarily.

• The customer shall not, under any circumstances, attempt to repair or tune the automatism. Must call qualified 

technician only.

• The installer must have certified professional knowledge at the level of mechanical assemblies in doors and 

gates and control board programmation. He should also be able to perform electrical connections in compliance 

with all applicable regulations.

• The installer should inform the customer how to handle the product in an emergency and provide him the 

manual.

ATTENTION:

This product is certified in accordance with European Community (EC) safety standards.

This product complies with Directive 2011/65/EU of the European Parliament and of the 

Council, of 8 June 2011, on the restriction of the use of certain hazardous substances in 

electrical and electronic equipment.

(Applicable in countries with recycling systems).

This marking on the product or literature indicates that the product and electronic 

accessories (eg. Charger, USB cable, electronic material, controls, etc.) should not be 

disposed of as other household waste at the end of its useful life. To avoid possible harm 

to the environment or human health resulting from the uncontrolled disposal of waste, 

separate these items from other types of waste and recycle them responsibly to promote 

the sustainable reuse of material resources. Home users should contact the dealer where 

they purchased this product or the National Environment Agency for details on where and 

how they can take these items for environmentally safe recycling. Business users should 

contact their vendor and check the terms and conditions of the purchase agreement. This 

product and its electronic accessories should not be mixed with other commercial waste.

This marking indicates that the product and electronic accessories (eg. charger, USB cable, 

electronic material, controls, etc.) are susceptible to electric shock by direct or indirect contact 

with electricity. Be cautious when handling the product and observe all safety procedures in 

this manual.  

Summary of Contents for MC50SC

Page 1: ...24V 1 2 v7 2 REV 03 2021 EN USER INSTALLER MANUAL MC50SC...

Page 2: ...P0 AUTOMATIC PROGRAMMING OF THE COURSE E2 COURTESY LIGHT TIME P6 SAFETY BAND P3 PEDESTRIAN COURSE TIME E6 DECELERATION SPEED P9 DISTANCE PROGRAMMING P1 SETTING THE DECELERATION TIME E3 FOLLOW ME P7 OP...

Page 3: ...not make any changes to the automation components and or their accessories Control board for indoor use with 230V connection Keep remote controls away from children to prevent the automated system fro...

Page 4: ...vated It is mandatory the use of limit switches Safety circuits 01 This input allows connection of safety bands The device operates according to programming set in the P6 menu page 10B 02 This input a...

Page 5: ...s not match the gate s movement turn off the control board from the power supply e swap the 5 and 7 wires from CN1 and check if it is correct with 3 and 4 from CN2 ESSENTIAL STEPS FOR INSTALLATION 03...

Page 6: ...cells in opening 00 00 10A Safety band Security Band Disabled Security Band Activated 8k2 input NC input Band in closure Band in opening 00 01 00 10B OperatiNG logic Automatic mode function Step by st...

Page 7: ...seconds 02 P0 appears Press MENU for 1 second 04 When MA appears press MENU for 1 second The motor will start a slow closing of the door 05 When it reach the closing limit switch it will open automati...

Page 8: ...vement inertia which could cause it to get stuck factory default 3 min max 0s 03 P1 appears Press MENU for 1 second 04 tP appears Press MENU for 1 second 06 Press MENU for 1 second to save the set val...

Page 9: ...P If you set the sensitivity FS to a value greater than 1 the force FO is automatically set to 9 without the possibility to change it Note If the control board has very high sensitivity values you ma...

Page 10: ...defined time Pause time adjustment of the total closure Allows you to set the time that the gate will remain open Pause time adjustment of the pedestrian closure Allows you to set the time that the ga...

Page 11: ...ault 00 02 P0 appears Press five times 02 P0 appears Press six times 03 P5 appears Press MENU for 1 second 03 P6 appears Press MENU for 1 second 04 HE appears Press MENU for 1 second 01 Press MENU for...

Page 12: ...or control board start button factory default 00 02 P0 appears Press seven times 01 Press MENU for 3 seconds 03 P7 appears Press MENU for 1 second 05 Press MENU to save the defined function 04 Appear...

Page 13: ...viously stored transmitter memorize transmitters page 5B Factory default 00 Distance programming operation PGM ON Press the keys indicated in the picture at the same time for 10 seconds and the flashi...

Page 14: ...ned function SOFT START 01 Press MENU for 10 seconds 02 E0 appears Press twice 03 E2 appears Press MENU for 1 second 05 Press MENU to save the defined time This menu allows you to define the time from...

Page 15: ...es 03 E3 appears Press MENU for 1 second 05 Press MENU to save the defined function 06 E4 appears is inactive To advance to the E5 menu press once To exit the programming press simultaneously 00 disab...

Page 16: ...maneuver it is understood by opening and closing The control board reset does not erase the maneuvers count Example 13456 maneuvers 01 Hundreds of thousands 34 Thousands 56 Dozens display flashes disp...

Page 17: ...ds RGB OUTPUT 05 Press MENU for 1 second to save the defined function 06 E1 appears To exit the programming press simultaneously 01 Press MENU for 10 seconds 02 E0 appears Press eight times 02 E0 appe...

Page 18: ...t switch enabled No limit switches or both open limit switches In pause time Security Band under pressure In pedestrian pause time Pedestrian button being pressed Memory full Start button being presse...

Page 19: ...ion correctly The order of capacitor wires linked with the automatism wires are not important as long as you link one to the Brown wire and the other to the Black one The common wire of the motor must...

Page 20: ...works the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motor doesn t work remove them from installation site and send to our MOTORL...

Page 21: ...1 2 3 4 5 6 7 8 9 V R G B RG DV 12 24V DV 12 24V COM NC CN1 CN2 CN3 CN4 CN5 20 EN Antenna Limit switch CLOSE OPEN key selector pushbutton Pedestrian key selector pushbutton Total Safety Band or or Pho...