INITIAL CONFIGURATION
REMOVE ALL CARDS
To make any programming or changing the operating parameters, it is necessary that unauthorized
modifications to the definitions do not occur.
All settings shown in "STANDALONE PROGRAMMING" can be changed by connecting the device
to the M-ACCESS software.
Control code 10
. Sets the duration of the door opening time after reading the valid card or pressing the
output button. (Predefined = 40 means 4 sec.) The time can be set from 1 to 6000 (drive = 0.1 sec.).
Control Code 11
. Applicable only if the door sensor is installed. The default value is 0, which means
that this function is disabled. The sensor detection time can be set from 1 to 6000 (drive = 0.1 sec.).
When the door sensor detection time has been set, the system will monitor the status of the door. If the
assigned door has expired, the controller will emit continuous sound signals. The door must be closed
for the controller to quit the alarm. However, if the door was forced to open, the controller will activate
the alarm relay to alert the administrator. To deactivate the alarm relay, enter the disarmament code.
ADD CARD
REMOVE CARD
SET DOOR OPEN TIME
SET DOOR SENSOR DETECTION TIME
OPERATIONS
INSTRUCTIONS
01 •
Enter programming mode
Master code
*
#
(The default master code is 30191000)
02 •
Enter the control code 01
01 #
03 •
Pass the card into the reader
Mifare Card
04 •
Enter password
4 digits
#
(If you do not want to set the pin again press #)
05 •
Exit programming mode
#
OPERATIONS
INSTRUCTIONS
01 •
Enter programming mode
Master code
*
#
(The default master code is 30191000)
02 •
Enter the control code 03
03 #
03 •
Exit programming mode
#
OPERATIONS
INSTRUCTIONS
01 •
Enter programming mode
Master code
*
#
(The default master code is 30191000)
02 •
Enter the control code 02
02 #
03 •
Pass the card in the reader
Mifare Card
04 •
Exit programming mode
#
OPERATIONS
INSTRUCTIONS
01 •
Enter programming mode
Master code
*
#
(The default master code is 30191000)
02 •
Enter the control code 10
10 #
03 •
Enter time
04 •
Exit programming mode
#
Desired time
OPERATIONS
INSTRUCTIONS
01 •
Enter programming mode
Master code
*
#
(The default master code is 30191000)
02 •
Enter control code 11
11 #
03 •
Enter time
Desired time
04 •
Exit programming mode
#
06. STANDALONE PROGRAMMING
06. STANDALONE PROGRAMMING