Sarix Professional 4 Bullet Camera Installation Manual
C6726M | 11/22
18
Connection Status LED Indicator
Once connected to the network, the green Connection Status LED indicator will display the progress in
connecting to the Network Video Management software.
The following table describes what the LED indicator shows:
Connection State Connection
Status LED
Indicator
Description
Obtaining
IP Address
One short flash
every second
Attempting to obtain an IP address.
Discoverable
Two short flashes
every second
Obtained an IP address but not connected to the
Network Video Management software.
Upgrading
Firmware
Two short flashes
and one long flash
every second
Updating the firmware.
Connected
On
Connected to the Network Video Management software.
The default connected setting can be changed to Off using
the camera's web user interface. For more information, see
the Pelco Sarix Professional 4 Bullet Camera Operations
Manual.
Troubleshooting Network Connections and LED Behavior
For any of the below LED behaviors, ensure that the camera is getting power and is using a good
network cable before trying another solution.
LED Behavior
Suggested Solution
Green LED is off and amber is on
Perform a factory reset of the camera using the physical
firmware revert button. Resetting through the camera's web
interface will not produce the desired result.
Both LEDs are off and the camera is not
connected or streaming video
Check the General setup page in the camera's web interface
to ensure the LEDs are not disabled.
If the LEDs are not disabled, perform a factory reset of the
camera using the physical firmware revert button. Resetting
through the camera's web interface will not produce the
desired result.
Both LEDs are blinking several times at
the same time, then pause and repeat
the blinking
Perform a factory reset of the camera using the physical
firmware revert button. Resetting through the camera's web
interface will not produce the desired result.
A different LED blinking pattern than
those described above
Perform a factory reset of the camera using the physical
firmware revert button. Resetting through the camera's web
interface will not produce the desired result.