Diagnostic Commands
RF-Conductor! Controller NIU Remote Configuration
5-18
6880494G55-O
May 1998
Setting Bit Error Rate (BER) Limit
This command is used to set BER high and low limit. The limits for high and low BER are
inter-dependent. High BER cannot be less than low BER and low BER cannot be more than
high BER at any given time.
1.
From the Diagnostic menu, use the
<tab>
to position the cursor to the left of the listing
Set
BER Limit
and press:
<Return>
Figure 5-17: Diagnostics Screen—Set BER Limit
The Set Ber Limit screen appears (see Figure 5-18). The high and low BER values define a
hysteresis function. The valid range for BER values is 0-65535. Initially, the range for high
BER will be 450-65535, and the range for low BER will be 0-800.
The factory default values: High BER value = 800 x 10
-6
, Low BER value = 450 x 10
-6
2.
Enter the value for the high BER rate press:
<Return>
.
3.
Enter the value for the low BER rate press:
<Return>
.