2-18
56F805EVM Hardware User’s Manual
MOTOROLA
2.16.2 Secondary UNI-3 Motor Protection Logic
The Secondary UNI-3 interface is similar to the Primary UNI-3 interface. The Secondary
UNI-3 Over-Voltage signal is connected to the controller’s PWM group B’s fault input,
device’s FAULTB0. The three Secondary UNI-3 Phase Over-Current signals are
connected to the controller’s PWM group B fault inputs, i.e., FAULTB1, FAULTB2 and
FAULTB3. The Secondary UNI-3 interface is similar to the circuits contained in
. The FAULTB1 input can be sourced from the Phase A Over-Current circuit
or the DC Bus Over-Current circuit. Jumper JG16 provides the selection; reference
Figure 2-13. DC-Bus Over-Voltage and Phase Over-Current Detection Circuits
+5.0V
+
–
+5.0V
+3.3V
V_sense_DCB
FAULT0
LM393
+
–
+5.0V
+5.0V
+3.3V
FAULT2
PHB_IS
LM393
DC BUS VOLTAGE SENSE
EXAMPLE DC PHASE CURRENT SENSE