From the Configure menu, select Configure Network
Services -> Mnemonic Table. Then configure the
following
Prompt
Enter
Result/Description
Entry
Number:
1
References this
table record.
Mnemonic
Name:
SDLC1001
Identifies the
mnemonic name
9
Call
Parameters:
1000201
Identifies the
location to send the
autocall. The
convention is to
identify the node
and port number in
this parameter
The Mnemonic
table appears.
From the Configure menu, select Configure FRI
Stations. Then configure the following.
Prompt
Enter
Result/Description
Port Number: 1
Identifies port
number 1 of this
node.
Station
Number:
1
Identifies the
station being
configured.
Station Type:
ANNEX_G
Adds a packet
header and LAPB
header to frame for
reliability checking
between Frame
Relay stations.
Link
Address:
DTE
Specifies the type
of link address
No. of PVC
Chan:
0
Specifies the
number of channels
used for Permanent
Virtual Circuits.
10
No. of SVC
Chan:
16
Specifies the
number of logical
SVC channels on
this port.
The FRI Stations
table appears.