SLIP to Frame Relay Annex G
Application Description
This application allows for a Switched Virtual Circuit connection between the
SLIP port and the Frame Relay Service. The SLIP connection requires the
Network to establish the connection. Please note that SLIP does not support PVC
Connections over Annex G stations.
The Frame Relay Port uses the Control Protocol Support ANSI T1.617 Annex D.
The Station's DLCI number is auto learned.
The Network service will need to call the Node with an address that has the
subaddress equal to the SLIP port number (i.e.,
757503
is valid for connection to
SLIP-3,
999902
is valid for SLIP-2.)
Configuration Summary
Port #1 FRI Annex D, ext clk, 1 Auto- learn DLCI Annex G
Port #2 SLIP RFC1490 encapsulation, 57600, Auto detect comp
Port #3 SLIP RFC1490 encapsulation, 57600, Auto detect comp.
•
Connections achieved by the Network Service calling the SLIP port.
•
CTP access via CTP switch or X.25 service calling subaddress 98.
Optional Application CMEMs
V1000004.MEM Standard application as mentioned in Summary
V1000004.001 Port #2 PAD, CTP access via PAD or switch
V1000004.002 Port #1 SLIP, Port #2 FRI
V1000004.003 Port #1 PAD, Port #2 FRI
V1000004.004 Port #1 NULL (no daughtercard), Port #2 FRI