Issue 1.1 April 2006
Page 44
7.7.9 Mounting The Canopy 150/300 PIDU
This step is optional. Motorola recommends that you mount the 150/300 PIDU on a wall or
other suitable mounting surface. This prevents the unit from being knocked or kicked and can
help maintain link availability. Ensure that the reset switch can be accessed when mounting
the unit.
Step 1: Fix the 150/300 PIDU to the wall using the lugs provided.
Step 2: Make connections as per Section 7.7.7.
WARNING
The 150/300 PIDU is not waterproof and should be mounted away from sources
of moisture. If mounted outdoors the 150/300 PIDU should be mounted in a rain proof
enclosure, preferably ventilated.
It is also recommended that you fit a drip loop on the 150/300 PIDU to ODU cable to ensure
that any moisture that runs down the cable into the cabinet or enclosure cannot enter the
150/300 PIDU. As shown in Figure 18 the network connection and mains cable should be
treated in the same way if there is a risk that they can carry moisture to the 150/300 PIDU.