9 Recovery
Mode
The Canopy 150/300 Mb BH has a special mode of operation that allows the user to recover
a unit from configuration errors or software image corruption.
Recovery mode is entered by depressing the Recovery Switch located on the underside of
the Canopy 150/300 PIDU while applying mains power, as shown in section 3.2.2. The
Recovery Switch should be held in the depressed state for between 10 and 20 seconds after
the application of mains power. The Ethernet LED will flash with 10 double flashes at power
up.
When in recovery mode the user will be able to access the unit via the Ethernet interface. The
Ethernet interface will have its IP address set to 169.254.1.2 on connection to a unit in
recovery mode the following screen is displayed (Figure 74):
Figure 73: Recovery Mode Warning Page
Clicking on the warning page image will take the user on to the Recovery Option Page (See
Figure 74).