Issue 1.1 April 2006
Page 127
11.6 Environmental Specifications
Category Specification
Temperature
ODU: -40°F (-40°C) to 140°F (+60°C)
150/300 Mbps Backhaul PIDU (SPIDU): 32°F (0°C) to
140°C)
150/300 Mbps Backhaul PIDU: -40°F (-40°C) to 140°F
(+60°C)
Wind Loading
151mph Max (242kph). See section 13 “Wind Loading” for a
full description.
Humidity
100% Condensing
Waterproof
IP65 (ODU), IP53 (150/300 Mbps Backhaul PIDU)
UV Exposure
10 year operational life (UL746C test evidence)
Standard Channel Raster (low channel set to 5742MHz), Channels 0/9 are limited to operate at 21dBm Max
Low Channel set to 5740MHz, Channel 0 is limited to operate at 17dBm Max, Channel 9 at 21dBm Max
Low Channel set to 5744MHz, Channel 0 is limited to operate at 21dBm Max, Channel 9 at 17dBm Max
Low Channel set to 5746/8MHz, Channel 0 is limited to operate at 21dBm Max, Channel 9 is not allowed
Summary of Contents for Canopy 150 Mbps Backhaul
Page 1: ...Canopy 150 300 Mbps Backhaul User Guide BH150 300 UG en Issue 1 1 April 2006 ...
Page 25: ...Issue 1 1 April 2006 Page 24 Figure 5 Canopy 150 300 PIDU Power Input ...
Page 97: ...Issue 1 1 April 2006 Page 96 Figure 59 Spectrum Management Help Page ...
Page 162: ...Issue 1 1 April 2006 Page 161 Figure A8 Surge Arrestor ALPU ORT Connection Illustration ...