2.4.6
Configure
Timing
Before the timing may be configured, you need to determine the network timing scheme
to be used. You also need to identify the master and slave devices for the end-user PBX
equipment.
Procedure 13: Configuring timing using the CLI
Action Steps
Log in
Press Enter.
At the
username
prompt, enter
admin
.
At the password prompt, enter
password
.
Set master clock
reference line
NOTE:
This is the master clock reference for all four T1/E1 lines.
The default setting is T1/E1 Port 1.
Enter set master clock reference line [1/2/3/4]
where
[1/2/3/4]
represents T1/E1 ports 1 through 4.
RESULT:
The system responds
Clk ref line; [1,2,3,4]
Set backup clock
reference line
NOTE:
This is the optional backup clock reference for all four T1/E1 lines. The
backup clock reference becomes active only when the master clock reference
line is unavailable. The default setting is T1/E1 Port 2.
Enter
set secondary clock reference line [1/2/3/4]
where
[1/2/3/4]
represents T1/E1 ports 1 through 4.
RESULT:
The system responds
Backup clk ref line; [1/2/3/4]
Issue