CPU12
INSTRUCTION GLOSSARY
MOTOROLA
REFERENCE MANUAL
6-197
Operation:
(A)
⇒
B
Description:
Moves the content of accumulator A to accumulator B. The former con-
tent of B is lost; the content of A is not affected. Unlike the general trans-
fer instruction TFR A,B which does not affect condition codes, the TAB
instruction affects the N, Z, and V status bits for compatibility with
M68HC11.
Condition Codes and Boolean Formulas:
Addressing Modes, Machine Code, and Execution Times:
TAB
Transfer from Accumulator A
to Accumulator B
TAB
S
X
H
I
N
Z
V
C
–
–
–
–
∆
∆
0
–
N:
Set if MSB of result is set; cleared otherwise.
Z:
Set if result is $00; cleared otherwise.
V:
0; Cleared.
Source Form
Address Mode
Object Code
Cycles
Access Detail
TAB
INH
18 0E
2
OO
Summary of Contents for CPU12