Operating Modes
Triple Timer Module
9
-17
Figure 9-14. Period Measurement Mode, TRM = 0
Mode 5 (internal clock): TRM = 0
N = write preload
M = write compare
TE
Clock
(CLK/2 or prescale CLK)
TLR
TCR
Counter
first event
M
0
N
N + 1
M
M + 1
N + 1
N
NOTE: If INV = 1, a 1-to-0 edge on TIO loads the counter, and a 0-to-1 edge on TIO
TCF (Compare Interrupt if TCIE = 1)
TIO pin
period being measured
loads TCR with count and the counter with N.
Interrupt Service
reads TCR; period
= M - N clock
periods
Counter continues
counting, does
not stop. Overflow
may occur (TOF=1).
Summary of Contents for DSP56303
Page 1: ...DSP56303 User s Manual 24 Bit Digital Signal Processor DSP56303UM AD Revision 1 January 2001 ...
Page 52: ...JTAG OnCE Interface 2 22 DSP56303 User s Manual ...
Page 114: ...General Purpose Input Output GPIO 5 10 DSP56303 User s Manual ...
Page 212: ...GPIO Signals and Registers 8 26 DSP56303 User s Manual ...
Page 268: ...Interrupt Equates A 22 DSP56303 User s Manual ...
Page 306: ...Programming Sheets B 38 DSP56303 User s Manual ...
Page 320: ...Index 14 DSP56303 User s Manual ...