29
ENVIRONOMENTAL SPECIFICATIONS
Operational
Temperature
(without degradation)
32º F (0º C) to 122º F (50º C).
See below * for operation between
-18º F (-28º C) to 32× F (0º C)
Storage Temperature
-22º F (-30º C) to 158º F (70º C), 24 hours
soak, without battery
Humidity
8 hours at 122º F (50º C) 5-95% RH with
power off during soak time. The unit will
then be turned ON and fully tested while in
the temp & humidity conditions. Battery
charging is automatically stopped above 95º
F (35º C).
Dripping Rain
MIL-STD-810F, Method 506.4 Proc II –
water tightness
Altitude
According to IEC 68-2-13/MIL-STD-810F,
Method 500.4
Operating 15,000 ft (4.5 km)
Blowing Dust
MIL-STD-810F, Method 510.4 Proc I – blow-
ing dust
Shock (Functional)
Total 18 impacts, hard mounted.
Operating: 15g, 11ms, half sine wave
Non-operating: 30g, 11ms, half sine wave
Vibration
Duration 1 hour/axis, hard mounted.
Operating: 10-55 Hz, 0.075 mm, 55-500 Hz,
1.0g
Non-operating: 10-55 Hz, 0.15 mm, 55-500
Hz, 2.0g
Drop
MIL-STD-810F, Method 516.5, 26 drops
from 4 ft. high.
Test surface: concrete
Enclosure Class
(Rain & Dust)
IP X4 (Rain)
IP 5X (Dust) Category 2 (no vacuum pump)